首页> 外文OA文献 >Recent Results on the Accurate Measurements of the Dielectric Constant of Seawater at 1.413GHZ
【2h】

Recent Results on the Accurate Measurements of the Dielectric Constant of Seawater at 1.413GHZ

机译:精确测量1.413GHZ海水介电常数的最新结果

摘要

Measurements of the complex. dielectric constant of seawater at 30.00 psu, 35.00 psu and 38.27 psu over the temperature range from 5 C to 3 5 at 1.413 GHz are given and compared with the Klein-Swift results. A resonant cavity technique is used. The calibration constant used in the cavity perturbation formulas is determined experimentally using methanol and ethanediol (ethylene glycol) as reference liquids. Analysis of the data shows that the measurements are accurate to better than 1.0% in almost all cases studied.
机译:测量复杂。给出了在1.413 GHz下从5 C到3 5的温度范围内的30.00 psu,35.00 psu和38.27 psu海水的介电常数,并将其与Klein-Swift结果进行了比较。使用了谐振腔技术。使用甲醇和乙二醇(乙二醇)作为参考液体,通过实验确定空腔扰动公式中使用的校准常数。数据分析表明,在几乎所有研究的案例中,测量结果的准确度均优于1.0%。