A PRSEUS test article was subjected to controlled impact on the skin face followed by static and cyclic axial compressions. Phased array ultrasonic inspection was conducted before impact, and after each of the test conditions. A linear phased array probe with a manual X-Y scanner was used for interrogation. Ultrasound showed a delamination between the skin and stringer flange adjacent to the impact. As designed, the stitching in the flange arrested the lateral flaw formation. Subsequent ultrasonic data showed no delamination growth due to continued loading. Keywords: Phased Array, Ultrasonics, Composites, Out-of-Autoclave
机译:PRSEUS测试产品在皮肤表面受到可控的冲击,然后进行静态和循环轴向压缩。在冲击之前和每个测试条件之后进行相控阵超声检查。使用带有手动X-Y扫描仪的线性相控阵探针进行询问。超声显示,皮肤和邻近冲击的纵梁之间出现分层。按照设计,法兰中的缝线阻止了横向缺陷的形成。随后的超声数据显示由于持续加载而没有分层增长。关键字:相控阵,超声,复合材料,高压灭菌器