首页> 外文OA文献 >Induced draft (ID) fan lubrication system design review and proposed modification upgrade at Callide C Power Station
【2h】

Induced draft (ID) fan lubrication system design review and proposed modification upgrade at Callide C Power Station

机译:Callide C电站引风机(ID)风机润滑系统设计审查和建议的升级改造

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

[Abstract]: Australia’s coal fired power stations are the most efficient form of providing bulk base load power generation (i.e. electricity) to consumers. This is dueudto Australia having an abundance of thermal coal reserves, which is the fuel used in coal fired power stations. Therefore it is extremely important that these power stations operate at maximum availability and reliability to ensure the consumer receives cost effective and uninterrupted electricity.ududCallide C Power Station in Biloela Queensland is a 900 Megawatt (MW) coal fired power station that was commissioned in 2001. Unfortunately Callide C Power Station has been plagued with continuous operational and reliabilityudproblems caused from the induced draft (ID) fans since initial commissioning. The ID fan problems have arisen from the bearing lubrication system which provides oil recirculation to the induction motor bearings and fan main shaft bearings. Consequently these issues have caused half-load unit (225 MW) run-backs and full unit (450 MW) trips over the past decade.ududThis project’s aim is to analyse the ID fan lubrication system and then identify and define all root causes and their associated failure modes. Once all root causes are identified through Root Cause Analysis (RCA) process,udeffective design solutions can be researched and evaluated so a proposed modification design project can be finalised. This final design proposal will be used to justify capital expenditure so implementation can occur in the near future.
机译:[摘要]:澳大利亚的燃煤发电站是向消费者提供大量基本负荷发电(即电力)的最有效形式。这归功于澳大利亚拥有丰富的动力煤储备,这是燃煤发电站中使用的燃料。因此,这些电站必须以最大的可用性和可靠性运行,以确保消费者获得经济高效且不间断的电力,这一点极其重要。自2001年以来,不幸的是,Callide C电站自首次试运行以来就一直遭受着引风机(ID)风扇引起的持续运行和可靠性问题的困扰。 ID风扇问题是由轴承润滑系统引起的,该系统为感应电动机轴承和风扇主轴轴承提供机油再循环。因此,在过去十年中,这些问题已导致半负载装置(225 MW)的运行回退和完整装置(450 MW)的跳闸。原因及其相关的故障模式。一旦通过根本原因分析(RCA)过程确定了所有根本原因,就可以研究和评估无效的设计解决方案,从而可以完成拟议的修改设计项目。该最终设计方案将用于证明资本支出的合理性,以便在不久的将来进行实施。

著录项

  • 作者

    Baker Stuart;

  • 作者单位
  • 年度 2010
  • 总页数
  • 原文格式 PDF
  • 正文语种 {"code":"en","name":"English","id":9}
  • 中图分类

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号