首页> 外文OA文献 >Electrochemical probing of selective haemoglobin binding in hydrogel-based molecularly imprinted polymers
【2h】

Electrochemical probing of selective haemoglobin binding in hydrogel-based molecularly imprinted polymers

机译:基于水凝胶的分子印迹聚合物中选择性血红蛋白结合的电化学探测

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

An electrochemical method has been developed for the probing of hydrogel-based molecularly imprinted polymers (HydroMIPs) on the surface of a glassy carbon electrode. HydroMIPs designed for bovine haemoglobin selectivity were electrochemically characterised and their rebinding properties were monitored using cyclic voltammetry. The electrochemical reduction of bovine oxyhaemoglobin (BHb) in solution was observed to occur at −0.460 V vs (Ag/AgCl) in 150 mM phosphate buffer solution (PBS). When the protein was selectively bound to the MIP, the electrochemical reduction of oxyhaemoglobin could be observed at a similar peak potential of −0.480 V vs (Ag/AgCl). When analysing the non-imprinted control polymer (NIP) interfaced at the electrode, which contained no protein, the peak reduction potential corresponded to that observed for dissolved oxygen in solution (−0.65 V vs (Ag/AgCl)). MIP and NIP (in the absence of protein) were interfaced at the electrode and protein allowed to diffuse through the polymers from the bulk solution end to the electrode. It was observed that whereas NIP exhibited a protein response within 10 min of protein exposure, up to 45 min of exposure time was required in the case of the MIP before a protein response could be obtained. Our results suggest that due to the selective nature of the MIP, BHb arrival at the electrode via diffusion is delayed by the MIP due to attractive selective interactions with exposed cavities, but not the NIP which is devoid of selective cavities.
机译:已经开发出一种电化学方法来探测玻璃碳电极表面上的基于水凝胶的分子印迹聚合物(HydroMIP)。设计用于牛血红蛋白选择性的HydroMIPs进行电化学表征,并使用循环伏安法监测其重新结合性能。相对于(Ag / AgCl)在150 mM磷酸盐缓冲溶液(PBS)中的-0.460 V,观察到溶液中牛氧血红蛋白(BHb)的电化学还原。当蛋白质选择性地结合到MIP上时,可以在-0.480 V vs(Ag / AgCl)的相似峰值电势下观察到氧血红蛋白的电化学还原。当分析在电极上不包含蛋白质的非印迹对照聚合物(NIP)时,峰还原电位对应于溶液中溶解氧的峰还原电位(-0.65 V对(Ag / AgCl))。 MIP和NIP(在不存在蛋白质的情况下)在电极处连接,蛋白质可以通过聚合物从本体溶液末端扩散到电极。观察到,尽管NIP在蛋白质暴露10分钟内显示出蛋白质反应,但对于MIP,在获得蛋白质反应之前最多需要45分钟的暴露时间。我们的结果表明,由于MIP的选择性,BHb通过扩散到达电极的时间由于与裸露的腔体之间的有吸引力的选择性相互作用而被MIP延迟,但没有缺少选择性腔体的NIP却不能。

著录项

  • 作者

    Reddy, SM; Sette, G; Phan, Q;

  • 作者单位
  • 年度 2011
  • 总页数
  • 原文格式 PDF
  • 正文语种 {"code":"en","name":"English","id":9}
  • 中图分类

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号