Heat Transfer Measurement in a Three-Phase Direct-Contact Condenser under Flooding Conditions

机译:淹没条件下三相直接接触式冷凝器的传热测量

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The transient temperature distribution and volumetric heat transfer coefficient during the 16 inception of flooding in a three-phase bubble type direct contact condenser have been 17 experimentally investigated. The flooding mechanism and the factors affecting the onset of 18 flooding of the three-phase direct contact column are not considered. A short Perspex column 19 of 70 cm total height and 4 cm internal diameter utilising two immiscible fluids was studied. 20 Pentane vapour with initial temperatures of 40°C, 43.5°C and 47.5℃ was the dispersed phase 21 and tap water at a constant temperature (19℃) was the continuous phase. Only 48 cm of the 22 column was used as the active height and different mass flow rates of both phases were used. 23 The experimental results showed that the instantaneous temperature distribution along the 24 direct contact column tends to be uniform when the direct contact column is working under 25 flooding conditions. Furthermore, the volumetric heat transfer coefficient increases as the 26 dispersed mass flow rate is increased towards the flooding limit and remains constant along 27 the column height. In addition, the dispersed phase mass flow rate that leads to flooding 28 increased with increasing mass flow rate of the continuous phase. The initial temperature of 29 the dispersed phase did not have a considerable effect on the flooding inception limit under 30 the present experimental conditions
机译:实验研究了17个三相气泡型直接接触式冷凝器中水淹16开始时的瞬态温度分布和体积传热系数。没有考虑三相直接接触柱的驱油机理和影响18次驱油开始的因素。研究了使用两种不混溶流体的总高度为70厘米,内径为4厘米的短有机玻璃柱19。初始温度为40°C,43.5°C和47.5℃的20 Pentane蒸气为分散相21,恒温(19℃)的自来水为连续相。 22色谱柱仅使用48 cm作为有效高度,并且使用了不同的两相质量流速。 23实验结果表明,当直接接触塔在25个驱油条件下工作时,沿着24个直接接触塔的瞬时温度分布趋于均匀。此外,体积传热系数随着26的分散质量流量向着溢流极限的增加而增加,并沿27的塔高保持恒定。另外,导致溢流28的分散相质量流量随着连续相质量流量的增加而增加。在目前的实验条件下,分散相的初始温度为29,对注水极限没有太大影响。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号