At the Paul Scherrer Institut, a personal neutron dosimetry system based on chemically etched poly allyl diglycol carbonate (PADC) detectors and an automatic track counting (Autoscan 60) for neutron dose evaluations has been in routine use since 1998. Today, the hardware and the software of the Autoscan 60 are out of date, no spare components are available anymore and more sophisticated image-analysis systems are already developed. Therefore, a new evaluation system, the ‘TASLIMAGE', was tested thoroughly in 2009 for linearity, reproducibility, influence of etching conditions and so forth, with the intention of replacing the Autoscan 60 in routine evaluations. The TASLIMAGE system is based on a microscope (high-quality Nikon optics) and an ultra-fast three-axis motorised control for scanning the detectors. In this paper, the TASLIMAGE system and its possibilities for neutron dose calculation are explained in more detail and the study of the influence of the variation of etching conditions on the sensitivity and background of the PADC detectors is described. The etching temperature and etching duration were varied, which showed that the etching conditions do not have a significant influence on the results of non-irradiated detectors. However, the sensitivity of irradiated detectors decreases by 5 % per 1°C when increasing the etching temperature. For the variation of the etching duration, the influence on the sensitivity of irradiated detectors is less pronounced
机译:在Paul Scherrer研究所,基于化学刻蚀的聚烯丙基碳酸二烯丙酯(PADC)检测器和用于中子剂量评估的自动跟踪计数(Autoscan 60)的个人中子剂量测定系统自1998年以来已投入日常使用。今天,硬件和Autoscan 60的软件已过时,不再有可用的备用组件,并且已经开发出了更复杂的图像分析系统。因此,新的评估系统“ TASLIMAGE”已于2009年进行了线性,可重复性,蚀刻条件影响等方面的全面测试,目的是在常规评估中取代Autoscan 60。 TASLIMAGE系统基于显微镜(高质量的尼康光学器件)和用于扫描探测器的超快速三轴电动控件。在本文中,将详细说明TASLIMAGE系统及其中子剂量计算的可能性,并研究刻蚀条件变化对PADC检测器的灵敏度和背景的影响。刻蚀温度和刻蚀持续时间各不相同,这表明刻蚀条件对未辐照检测器的结果没有显着影响。但是,当提高蚀刻温度时,辐照检测器的灵敏度每1°C降低5%。对于蚀刻持续时间的变化,对辐照探测器灵敏度的影响不太明显。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号