首页> 外文OA文献 >Psychophysical and electrophysiological responses to experimental pain may be influenced by sedation: comparison of the effects of a hypnotic (propofol) and an analgesic (alfentanil)
【2h】

Psychophysical and electrophysiological responses to experimental pain may be influenced by sedation: comparison of the effects of a hypnotic (propofol) and an analgesic (alfentanil)

机译:镇静可能会影响对实验性疼痛的心理和电生理反应:比较催眠药(异丙酚)和镇痛药(阿芬太尼)的镇静作用

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Sedation may influence the responses of some experimental pain models used to test analgesic efficacy. In this study we compared the effects of a sedative (propofol) and analgesic (alfentanil) on: nociceptive reflex to single and repeated electrical stimulations; mechanical pressure pain; and evoked potentials elicited by nociceptive (electrical and laser) and non-nociceptive (acoustical) stimulation. We studied 12 healthy volunteers with two subanaesthetic concentrations of propofol and two analgesic concentrations of alfentanil. Both propofol and alfentanil increased the threshold for nociceptive reflex to single electrical stimulations, but only alfentanil increased the threshold for nociceptive reflex to repeated electrical stimulations. The pressure pain tolerance thresholds were increased significantly by alfentanil, whereas propofol significantly decreased the thresholds (hyperalgesia). Propofol and alfentanil induced similar reductions in the amplitudes of the evoked potentials elicited by nociceptive (electrical and laser) and non-nociceptive (acoustical) stimulation, whereas only alfentanil reduced the perceived pain to nociceptive stimulations. We have shown that sedation can influence both the psychophysical and electrophysiological responses of some experimental pain tests used to measure analgesic efficacy, and that propofol in subhypnotic doses, has no analgesic effect on painful electrical and heat stimulations, but has a hyperalgesic effect on mechanical pressure pain
机译:镇静可能会影响某些用于测试镇痛效果的实验性疼痛模型的反应。在这项研究中,我们比较了镇静药(异丙酚)和镇痛药(阿芬太尼)对单次或多次电刺激的伤害性反射;机械压力疼痛;以及由伤害性(电和激光)和非伤害性(声学)刺激引起的诱发电位。我们研究了十二种麻醉浓度为异丙酚的亚麻醉药和两种镇痛剂浓度为阿芬太尼的12名健康志愿者。异丙酚和阿芬太尼均增加了对单次电刺激的伤害性反射阈值,但只有阿芬太尼增加了对重复电刺激的伤害性反射的阈值。芬太尼显着提高了压力疼痛耐受性阈值,而丙泊酚显着降低了阈值(痛觉过敏)。异丙酚和阿芬太尼诱导类似的伤害性(电和激光)刺激和非伤害性(声学)刺激引起的诱发电位幅度降低,而只有阿芬太尼将伤害感降低到伤害性刺激。我们已经证明,镇静可以影响用于测量镇痛效果的一些实验性疼痛试验的心理,生理和电生理反应,并且亚催眠剂量的丙泊酚对疼痛的电刺激和热刺激没有镇痛作用,但对机械压力具有镇痛作用痛

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号