首页> 外文OA文献 >Single-use disposable electrochemical label-free immunosensor for detection of glycated hemoglobin (HbA1c) using differential pulse voltammetry (DPV)
【2h】

Single-use disposable electrochemical label-free immunosensor for detection of glycated hemoglobin (HbA1c) using differential pulse voltammetry (DPV)

机译:一次性使用的无电化学免标记免疫传感器,用于使用差分脉冲伏安法(DPV)检测糖化血红蛋白(HbA1c)

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

A single-use disposable in vitro electrochemical immunosensor for the detection of HbA1c in undiluted human serum using differential pulse voltammetry (DPV) was developed. A three-electrode configuration electrochemical biosensor consisted of 10-nm-thin gold film working and counter electrodes and a thick-film printed Ag/AgCl reference electrode was fabricated on a polyethylene terephthalate (PET) substrate. Micro-fabrication techniques including sputtering vapor deposition and thick-film printing were used to fabricate the biosensor. This was a roll-to-roll cost-effective manufacturing process making the single-use disposable in vitro HbA1c biosensor a reality. Self-assembled monolayers of 3-Mercaptopropionic acid (MPA) were employed to covalently immobilize anti-HbA1c on the surface of gold electrodes. Electrochemical impedance spectroscopy (EIS) and X-ray photoelectron spectroscopy (XPS) confirmed the excellent coverage of MPA-SAM and the upward orientation of carboxylic groups. The hindering effect of HbA1c on the ferricyanide/ferrocyanide electron transfer reaction was exploited as the HbA1c detection mechanism. The biosensor showed a linear range of 7.5-20 μg/mL of HbA1c in 0.1 M PBS. Using undiluted human serum as the test medium, the biosensor presented an excellent linear behavior (R2 = 0.999) in the range of 0.1-0.25 mg/mL of HbA1c. The potential application of this biosensor for in vitro measurement of HbA1c for diabetic management was demonstrated.
机译:开发了一种一次性的一次性体外电化学免疫传感器,用于使用差分脉冲伏安法(DPV)检测未稀释的人血清中的HbA1c。一种三电极结构的电化学生物传感器,由10纳米薄的金膜工作电极和对电极组成,并在聚对苯二甲酸乙二醇酯(PET)基板上制作了厚膜印刷的Ag / AgCl参比电极。微制造技术包括溅射气相沉积和厚膜印刷被用来制造生物传感器。这是一卷一卷的高性价比制造工艺,使一次性使用的一次性体外HbA1c生物传感器成为现实。使用3-巯基丙酸(MPA)的自组装单层将抗HbA1c共价固定在金电极表面。电化学阻抗谱(EIS)和X射线光电子能谱(XPS)证实了MPA-SAM的极佳覆盖范围和羧基的向上取向。 HbA1c对铁氰化物/亚铁氰化物电子转移反应的阻碍作用被用作HbA1c的检测机制。生物传感器在0.1 M PBS中显示HbA1c线性范围为7.5-20μg/ mL。使用未稀释的人血清作为测试介质,该生物传感器在0.1-0.25 mg / mL的HbA1c范围内表现出出色的线性行为(R2 = 0.999)。证明了这种生物传感器在体外测量HbA1c用于糖尿病治疗中的潜在应用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号