首页> 外文OA文献 >Compressive strength of steel single angles loaded through two-bolts in one leg.
【2h】

Compressive strength of steel single angles loaded through two-bolts in one leg.

机译:单腿通过两个螺栓加载的钢单角钢的抗压强度。

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

One hundred and ninety seven steel single angles loaded through two bolts in one leg were tested for their compressive strengths. They included five different sizes (76 x 51 x 6.4, 127 x 76 x 6.4, 64 x 64 x 6.4, 64 x 64 x 4.8, and 76 x 76 x 6.4 mm) and slenderness ratios varying from 69 to 201. The gauge distances were varied from the minimum to the maximum possible value for each size of angle. The effect of the connection type (snug tight and pretensioned) was also investigated. The effect of the width of the connected leg (long leg connected versus long leg out) was studied. All experimental failure loads were compared to CAN/CSA-S16.1-94 (Limit States Design of Steel structures), CSA-S37-94 (Antennas, Towers and Antenna Supporting Structures). It was shown that the S16.1 standard was extremely conservative while the S37 standard gave more realistic estimations. Variation of yield stress across the cross-section was determined for forty-two stock lengths of angles. Although the nominal yield stress was 300 MPa for all the specimens, the yield stresses determined ranged between 311 and 479 MPa with an average value of 363 MPa. Thirty-nine different stock lengths of steel angles were tested for the distribution of residual stresses. This distribution, however, did not show any specific pattern.Dept. of Civil and Environmental Engineering. Paper copy at Leddy Library: Theses u26 Major Papers - Basement, West Bldg. / Call Number: Thesis1996 .H34. Source: Masters Abstracts International, Volume: 37-01, page: 0312. Adviser: M. K. S. Madugula. Thesis (M.A.Sc.)--University of Windsor (Canada), 1997.
机译:测试了在一条腿中通过两个螺栓加载的一百九十七个钢单角的抗压强度。它们包括五种不同的尺寸(76 x 51 x 6.4、127 x 76 x 6.4、64 x 64 x 6.4、64 x 64 x 4.8和76 x 76 x 6.4毫米),细长比从69到201不等。每种角度的大小从最小到最大可能变化。还研究了连接类型(贴紧和预紧)的效果。研究了连接腿的宽度(连接的长腿与长腿)的影响。将所有实验失败载荷与CAN / CSA-S16.1-94(钢结构的有限状态设计),CSA-S37-94(天线,塔架和天线支撑结构)进行了比较。结果表明,S16.1标准非常保守,而S37标准则给出了更为现实的估计。对于42个角钢长度,确定了横截面的屈服应力变化。尽管所有样品的标称屈服应力均为300 MPa,但测得的屈服应力范围为311至479 MPa,平均值为363 MPa。测试了39种不同长度的角钢的残余应力分布。但是,这种分布没有显示任何特定的模式。土木与环境工程系。莱迪图书馆的纸质副本:论文主要论文-西楼地下室。 /电话:Thesis1996 .H34。资料来源:国际硕士摘要,卷:37-01,第0312页。顾问:M。K. S. Madugula。论文(硕士)-温莎大学(加拿大),1997年。

著录项

  • 作者

    Haidar Raymond.;

  • 作者单位
  • 年度 1997
  • 总页数
  • 原文格式 PDF
  • 正文语种
  • 中图分类

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号