首页> 外文OA文献 >Intra-operative dosimetry of trans-rectal ultrasound guided I prostate implants using C-arm fluoroscopic images.
【2h】

Intra-operative dosimetry of trans-rectal ultrasound guided I prostate implants using C-arm fluoroscopic images.

机译:使用C型臂透视图像对经直肠超声引导的I型前列腺植入物进行术中剂量测定。

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Permanent implantation of radioactive seeds is a viable and effective therapeutic option widely used today for early-stage prostate cancer. The implant technique has improved considerably during the recent years due to the use of image guidance; however, real-time dose distributions would allow potential cold spots to be assessed and additional seeds added. In this study, we investigate the use of a conventional C-arm fluoroscopy unit for image acquisition and evaluation of dose distribution immediately after the implant. The phantom study indicates that it is possible to obtain seed positions within ±2 mm. A pilot study carried out with three patients indicated that it is possible to obtain seed positions and calculate the dose distribution with C-arm fluoroscopy and about 95% of the seeds were reconstructed within ±2 mm. The results could be further improved with better digital imaging.
机译:永久植入放射性种子是当今广泛用于早期前列腺癌的可行和有效的治疗选择。近年来,由于使用了图像引导技术,植入技术得到了显着改善。但是,实时剂量分布将允许评估潜在的冷点并添加其他种子。在这项研究中,我们调查了使用常规C臂荧光透视仪进行图像采集并在植入后立即评估剂量分布的情况。幻像研究表明,可以获得±2 mm以内的种子位置。对三名患者进行的初步研究表明,可以使用C型臂透视检查获得种子位置并计算剂量分布,并且在±2 mm范围内重建了约95%的种子。更好的数字成像可以进一步改善结果。