首页> 外文OA文献 >Microporous hollow fibre membrane modules as gas-liquid contactors. Part 2. Mass transfer with chemical reaction
【2h】

Microporous hollow fibre membrane modules as gas-liquid contactors. Part 2. Mass transfer with chemical reaction

机译:微孔中空纤维膜组件作为气液接触器。第2部分。与化学反应的传质

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Absorption determined by mass transfer in the liquid is described well with the Graetz-Lévèque equation adapted from heat transfer. The influence of a chemical reaction on the mass transfer was simulated with a numerical model and tested on the absorption of CO2 in a hydroxide solution. Absorption determined by mass transfer in the gas phase and the pores of the membrane was also analysed experimentally and numerically. It was found that the gas phase concentration profile is established at a very short distance from the entrance of the fibre. This results in a constant Sherwood number along the fibre. A module coated with a very thin silicone rubber layer showed absorption rates comparable to the uncoated membranes. If absorption liquids are used which wet the membranes, resulting in leaky membranes, such a coating can enlarge the application of microporous hollow fibre membrane module.
机译:用传热改编的Graetz-Lévèque方程很好地描述了液体中传质确定的吸收。用数值模型模拟了化学反应对传质的影响,并测试了氢氧化物溶液中CO2的吸收。还通过实验和数值分析了由气相和膜孔中的传质确定的吸收。发现气相浓度分布建立在距纤维入口很短的距离处。这导致沿纤维的舍伍德数恒定。涂有非常薄的硅橡胶层的模块显示出与未涂膜相当的吸收率。如果使用吸收液润湿膜,导致膜泄漏,则这种涂层可以扩大微孔中空纤维膜组件的应用范围。