首页> 外文OA文献 >Liquid Chromatography Tandem Mass Spectrometry Measurements of Steroids in Biological Samples for Clinical Research Studies: Methodology and Application
【2h】

Liquid Chromatography Tandem Mass Spectrometry Measurements of Steroids in Biological Samples for Clinical Research Studies: Methodology and Application

机译:用于临床研究的生物样品中类固醇的液相色谱串联质谱测定方法和应用

摘要

The advent of liquid chromatography tandem mass spectrometry (LC-MS/MS) coupled with soft ionization method has expanded the scope for measurement of steroids from biological matrices with higher accuracy, specificity, sensitivity and requires less sample preparation. The overall aim of this study is to develop and validate LC-MS/MS methods to measure steroids from biological samples for clinical research studies. A sensitive and specific LC-MS/MS assay was developed and validated to measure steroids from dried blood spots (DBS) samples to assess the feasibility and pharmacology of subcutaneous (sc) injection of androgen ester in healthy men using DBS for frequent sampling. The study demonstrated a sustained release of this androgen ester which suggests that sc injections of testosterone esters may prove to be pharmacologically effective. A LC-MS/MS assay was also developed to measure urinary androgens and estrogen in adolescents and subsequently to relate the changes in the urinary sex hormones over 12 months to the standard anthropometric markers of puberty. We found that the urine hormone measurements correlated cross-sectionally and longitudinally with age, anthropometry and Tanner stage. We also investigated whether first morning void urine hormones in growing adolescents require adjustments for urine dilution/concentration and, if so, whether urinary creatinine or specific gravity (SG) are better adjustments. The study demonstrates that urine steroid and LH concentrations in first morning void samples of adolescents are not significantly influenced by hydration status and may not require adjustments; however, if desired, both creatinine and SG adjustments are equally suitable. We also assessed whether commercially available luteinizing hormone (LH) immunoassays (immunochemiluminometric, ICL and immunofluorometric, IF) previously validated for human blood samples is suitable for urine samples kept at prolonged frozen (4 years). We found that both immunoassays are suitable for urinary LH measurements with ICL assay being more robust for quantitative urinary LH measurement such as for anti-doping purpose whereas the IF could be applicable for research studies where urine LH levels are compared within-study but not in absolute terms.
机译:液相色谱串联质谱法(LC-MS / MS)结合软电离方法的出现,扩大了从生物基质中测量类固醇的范围,具有更高的准确性,特异性,灵敏度,并且所需的样品制备更少。这项研究的总体目标是开发和验证LC-MS / MS方法,以测量用于临床研究的生物样品中的类固醇。开发了一种灵敏且特异性的LC-MS / MS测定方法,并经过验证可测量干血斑(DBS)样品中的类固醇,以评估使用DBS进行频繁采样的健康男性皮下注射(sc)雄激素的可行性和药理作用。该研究证明了这种雄激素酯的持续释放,这表明皮下注射睾丸激素酯可能被证明在药理上是有效的。还开发了一种LC-MS / MS分析方法,用于测量青少年中的尿雄激素和雌激素,随后将12个月内尿中性激素的变化与青春期的标准人体测量学指标联系起来。我们发现尿激素测量结果与年龄,人体测量学和坦纳分期在横截面和纵向上相关。我们还调查了成长中的青少年在清晨的第一时间尿尿激素是否需要调整尿液的稀释/浓度,如果需要的话,尿肌酐或比重(SG)是否是更好的调整方法。该研究表明,青少年的第一天早晨空腹样本中的尿类固醇和LH浓度不受水合状态的显着影响,可能不需要进行调整。但是,如果需要,肌酐和SG调节都同样适用。我们还评估了先前针对人血样本验证的市售黄体生成素(LH)免疫测定(免疫荧光发光法,ICL和免疫荧光测定,IF)是否适合长时间冷冻(4年)的尿液样本。我们发现这两种免疫测定均适用于尿液LH的测量,而ICL测定法更适合定量尿液LH的测量,例如用于反兴奋剂的目的,而IF可能适用于研究尿液LH水平在研究内进行比较但在研究中不进行比较的研究。绝对条款。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号