摘要

The balanced fan depressurization method has been modified for application to high-rise apartment buildings in order to measure the overall air leakage and the wall air leakape of an apartment unit simultaneously. The method requires the use of two sets of fan pressurization apparatus. One is installed at the door of an apartment unit for measuring the air leakage rate of the exterior wall, and a much larger apparatus is installed at an exterior door of the building for measuring the overall air leakage rate. The pressures between thetest unit and the adjacenr units are balanced to minimize the air leakage through the party walls by adjusting the airflow of the larger apparatus and the door opening of the adjacent apartments. The method was successfully applied to two high-rise apartment towers before and after they were retrofitted to improve airtightness of the envelope. In addition, the tracer gas decay method was applied to the same buildings to obtain the infiltration rates of selected apartment units. The methods used to measure the airtightness values and the air infiltration rates and the test results of the two apartment towers are discussed.
机译:平衡风扇降压方法已经过修改,可应用于高层公寓楼,以便同时测量公寓单元的整体漏气和墙体漏气。该方法需要使用两组风扇增压装置。一个安装在公寓单元的门上,用于测量外墙的空气泄漏率,而更大的设备安装在建筑物的外门上,用于测量整体空气泄漏率。通过调节较大设备的气流和相邻公寓的门的开口,平衡测试单元和相邻单元之间的压力,以最大程度地减少通过聚会壁的漏气。该方法已成功应用于两座高层公寓大楼的改造前后,以改善围护结构的气密性。另外,示踪气体衰减法被应用于相同的建筑物,以获得选定公寓单元的渗透率。讨论了用于测量气密性值和空气渗透率的方法以及两个公寓塔的测试结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号