首页> 外文OA文献 >Assessing the effectiveness of wall-window interface details to manage rainwater - selected results from window installation to a wall sheathed in extruded polystyrene
【2h】

Assessing the effectiveness of wall-window interface details to manage rainwater - selected results from window installation to a wall sheathed in extruded polystyrene

机译:评估墙窗界面细节对雨水进行管理的有效性-从窗户安装到挤塑聚苯乙烯护套墙的选定结果

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The detailing of wall-window interfaces and the consequences of defective installation of windows is an on-going concern in North America. This manuscript concerns laboratory evaluation of the water leakage performance of a select set of window-wall interface details. The details were for windows with mounting flanges installed in wood-frame walls sheathed with rigid extruded polystyrene foam. The tests were performed on a single full scale test assembly in which two identical windows were installed by two similar but nonetheless different means. Each detail included a sill pan intended to collect water that gained entry into the assembly and thus was designed to be robust (tolerant of flaws). Tests were performed over a series of different water loading (spray) rates, and over a series of different air pressure differentials at each spray rate. Air leakage rates through the window opening were monitored; they were controlled by a unique methodology. Leakage paths were introduced in the window frames and these paths were alternatively blocked or opened to permit evaluation of the performance of the installation details under two different assumed conditions of window leakage. Air pressure distribution within the assemblies was monitored during spray testing. The wall assembly were designed to permit observation of water entry in it, and to allow measurement of water entry to, or drainage from, various locations within the assembly. Results on water entry and management for the two wall-window interface configurations are given and effectiveness of the details is discussed.
机译:壁窗接口的细节以及窗户安装不良的后果在北美一直是关注的焦点。该手稿涉及对一组选定的窗墙界面细节的漏水性能进行实验室评估。详细信息适用于带有安装法兰的窗户,该法兰安装在木结构墙壁上,并用硬质挤出聚苯乙烯泡沫包裹。测试是在单个满量程测试组件上执行的,其中通过两个相似但仍然不同的方法安装了两个相同的窗口。每个细节都包括一个用来收集积水的槛板,该积水进入了组件,因此坚固耐用(可容忍瑕疵)。测试是在一系列不同的水负载(喷射)速率下,以及在每个喷射速率下的一系列不同气压差下进行的。监测通过窗孔的漏气率;他们受到独特方法的控制。在窗框中引入了泄漏路径,并交替地阻塞或打开了这些路径,以允许在两种不同的假定窗户泄漏条件下评估安装细节的性能。在喷雾测试过程中监控组件内的气压分布。壁组件的设计允许观察其中的水进入,并允许测量水进入组件中各个位置或从其中排放的水。给出了两种壁窗接口配置的进水和管理结果,并讨论了细节的有效性。

著录项

相似文献

  • 外文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号