The application of a binary step-up method has been investigated at the Korea Research Institute of Standards and Science (KRISS) for establishment of high dc standards based on the calibration system of high dc shunts up to a few thousand amperes in which the current dependence of the shunt resistance can be measured. A successive step-up method with a pair of high dc shunts was suggested to link the unknown high current to the values of low current level which are already known. The step-up approach was further modified with employing a current monitor to extract the information on the current dependence of the shunt and the source current changes during the step-up measurement. To validate the modified step-up technology, a comparison of high dc shunt resistance was carried out with National Research Council (NRC) in which both the KRISS and the NRC results agreed well within the standard deviation of the measurement on the order of about 0.01%.
机译:韩国标准与科学研究院(KRISS)已研究了二进制升压方法的应用,以基于高达几千安培的高直流分流器校准系统建立高直流标准,其中电流依赖可以测量分流电阻的最大值。建议采用具有一对高直流分流器的连续升压方法,将未知的高电流链接到已知的低电流水平值。通过采用电流监控器来提取升压方法,以提取有关分流器电流依赖性的信息,并在升压测量期间获取源电流变化。为了验证改进的升压技术,与美国国家研究委员会(NRC)进行了高直流并联电阻的比较,在该比较中,KRISS和NRC结果均在约0.01的测量标准偏差内非常吻合%。