摘要

The performance of 3D Imaging Systems needs to be evaluated using a common terminology and test procedures. This evaluation is necessary because three-dimensional imaging systems are measuring instruments and the spatial coordinates they provide are only estimates of the 3D surfaces being sampled. These coordinates need to be completed by a quantitative statement about their uncertainty to be meaningful. The statement of uncertainty is based on comparisons with standards traceable to the national units of length (SI units). We describe and present experimental results of a procedure to evaluate distance measurement uncertainty of medium range laser scanners (range between 2-100m). The procedure is based on the evaluation of Point-to-Point distance errors using custom made Reference Test Object (RTO) and a certified 3D laser tracker as a reference. This work is proposed as a possible protocol to the American Society for Testing and Materials (ASTM)-E57.02 3D Imaging Systems standards committee on test methods.
机译:需要使用通用术语和测试程序来评估3D成像系统的性能。此评估是必要的,因为三维成像系统是测量仪器,它们提供的空间坐标只是对采样的3D表面的估计。这些坐标需要通过有关其不确定性的定量说明来完成,这样才有意义。不确定性声明基于与可追溯到国家长度单位(SI单位)的标准的比较。我们描述并介绍了评估中程激光扫描仪(范围在2-100m之间)的距离测量不确定度的过程的实验结果。该程序基于使用定制参考测试对象(RTO)和经过认证的3D激光跟踪仪作为参考的点对点距离误差的评估。这项工作是美国测试和材料协会(ASTM)-E57.02 3D成像系统标准委员会关于测试方法的可能协议。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号