首页> 外文OA文献 >Blank correction considerations for isotope dilution and reverse isotope dilution calibration: determination of methylmercury in fish tissue
【2h】

Blank correction considerations for isotope dilution and reverse isotope dilution calibration: determination of methylmercury in fish tissue

机译:同位素稀释和反向同位素稀释校准的空白校正注意事项:鱼组织中甲基汞的测定

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

A mathematical approach to the accurate correction of the blank when applying isotope dilution (ID) and reverse ID is presented. The manner in which blank correction is undertaken is critical to the quality of the final results. Direct subtraction of a procedural blank from the gross analyte concentration is only valid when the blank contributes to the primary ID process and not to the reverse ID process. When the blank contributes to both processes, typically only a fraction of this blank concentration should be subtracted. The approach developed here was illustrated and validated by the determination of MeHg in tuna fish using ID and reverse ID SPME GC-ICP-MS and an enriched Me198Hg spike. Despite a 150-fold higher blank (equivalent to 7% of the analyte concentration in the sample) arising from use of a 1 M NaOAc/HOAc buffer solution compared to that obtained with use of a 0.5 M NH4OAc/HOAc buffer, final concentrations of 19.90 \ub1 0.34 and 19.88 \ub1 0.10 \u3bcmol kg\u22121 (one standard deviation, n = 3) respectively, were derived. These data are in good agreement with the assigned value of 19.91 \ub1 0.82 \u3bcmol kg\u22121 (as 95% confidence interval, derived from an international intercomparison exercise). The methodology was also applied to the determination of a 50-fold lower concentration of MeHg in a salmon fish. A method detection limit (3SD) of 0.9 nmol kg\u22121 based on processing of a 0.40 g subsample was obtained.
机译:提出了一种在应用同位素稀释(ID)和反向ID时准确校正空白的数学方法。进行空白校正的方式对于最终结果的质量至关重要。从总分析物浓度中直接减去程序空白的方法仅在空白对主要ID程序而不是反向ID程序起作用的情况下才有效。当空白对这两个过程都有贡献时,通常只应减去空白浓度的一小部分。通过使用ID和反向ID SPME GC-ICP-MS以及富集的Me198Hg尖峰测定金枪鱼中的MeHg,说明并验证了此处开发的方法。尽管使用1 M NaOAc / HOAc缓冲溶液比使用0.5 M NH4OAc / HOAc缓冲溶液获得的空白高150倍(相当于样品中分析物浓度的7%),但最终浓度为分别得出19.90 \ ub1 0.34和19.88 \ ub1 0.10 \ u3bcmol kg \ u22121(一个标准偏差,n = 3)。这些数据与19.91 \ ub1 0.82 \ u3bcmol kg \ u22121的分配值非常吻合(95%置信区间,来自国际比较研究)。该方法还用于测定鲑鱼中低50倍的MeHg浓度。基于0.40 g子样品的处理,方法检出限(3SD)为0.9 nmol kg \ u22121。

著录项

  • 作者

    Yang, L.; Sturgeon, R.;

  • 作者单位
  • 年度 2005
  • 总页数
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号