Frost heave is an important consideration in the design of buried chilled pipelines. A procedure for calculating the amount of heave under a chilled gas pipeline is presented based on a finite-difference formulation of the heat and mass transfer in saturated soils. The frost heave of the soil is characterized in terms of the segregation potential concept developed in earlier papers by the authors. Good agreement is found between the predictions of heave obtained with this procedure and that observed in long-term full- scale experiments at a test site in Calgary, Canada. Additional calculations are presented to explore the influence of pipeline temperature, pipe insulation, and ground temperature on frost heave of buried pipelines.
机译:冻胀是地下冷却管道设计中的重要考虑因素。基于饱和土壤中传热与传质的有限差分公式,提出了一种计算冷气管道下的起伏量的程序。作者根据早期论文中提出的偏析潜力概念来表征土壤的冻胀。在通过此程序获得的升沉的预测与在加拿大卡尔加里的一个测试地点进行的长期全面试验中所观察到的预测之间发现了很好的一致性。提出了额外的计算方法,以探索管道温度,管道隔热和地面温度对埋地管道的冻胀的影响。