首页> 外文OA文献 >Calibration of heat flow meter apparatus used for quality control of low-density mineral fiber insulations
【2h】

Calibration of heat flow meter apparatus used for quality control of low-density mineral fiber insulations

机译:用于低密度矿物纤维绝缘材料质量控制的热流量计设备的校准

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

This paper provides industrial laboratories with guidelines for verifying precision in thermal resistance determinations. It deals with both equipment and test procedures, and discusses the development of a calibration program for the heat flow meter (HFM) apparatus used in quality control of low-density mineral fiber insulations manufactured at the Innisfail Plant of Manville Canada Inc. To ensure agreement between the HFM apparatus used in the plant and the guarded hot plate (GHP) apparatus used by National Research Council of Canada, the following elements were incorporated in the calibration program: selection, fabrication and verification of low-density glass fiber reference systems, calibration of apparatus, error analysis of apparatus, maintenance of calibration.
机译:本文为工业实验室提供了验证热阻测定精度的指南。它涉及设备和测试程序,并讨论了用于加拿大曼维尔Innisfail工厂生产的低密度矿物纤维绝缘材料质量控制的热流量计(HFM)设备的校准程序的开发。在工厂中使用的HFM设备与加拿大国家研究委员会使用的保护热板(GHP)设备之间,以下程序已包含在校准程序中:低密度玻璃纤维参考系统的选择,制造和验证,校准设备,设备错误分析,维护校准。