首页> 外文OA文献 >Reliability of the Elliptical Zone Method of Estimating Body Segment Parameters of Swimmers
【2h】

Reliability of the Elliptical Zone Method of Estimating Body Segment Parameters of Swimmers

机译:游泳者身体分段参数估计的椭圆带方法的可靠性

摘要

Due to the difficulty of measuring forces and torques acting on a swimmer during mid-pool swimming, an inverse dynamics approach is required. Personalised body segment parameter (BSP) data enabling calculation of net forces and torques can be obtained using the elliptical zone method. The purpose of this study was to establish the reliability of estimating BSP data of swimmers by the elliptical zone method with segment outlines being traced manually on a personal computer screen. Five assessors digitised the segment landmarks and traced the body segments from front and side view digital photographs of 11 single arm amputee swimmers. Each swimmer was assessed five times by each of the five assessors. The order was fully randomised. Within assessor variability was less than 5% for the segment centre of mass position of all segments, for segment length except the neck (5.2%), and for segment mass except neck (11.9%), hands (Left: 8.1%; Right: 5.8%) and feet (Left: 7.3%; Right: 7.3%). Analysis of mean variability within and between assessors indicated that between assessor variability was generally as large or larger than within assessor variability. Consequently it is recommended that when seeking personalised BSP data to maximise the accuracy of derived kinetics and sensitivity for longitudinal and bilateral within-subject comparisons the individual should be assessed by the same assessor with mean values obtained from five repeat digitisations. This study established that using the elliptical zone method using E-Zone software is a reliable and convenient way of obtaining personalised BSP data for use in analysis of swimming.
机译:由于在中池游泳期间难以测量作用于游泳者的力和扭矩,因此需要逆动力学方法。可以使用椭圆区域方法获得个性化的身体分段参数(BSP)数据,从而可以计算净力和扭矩。这项研究的目的是建立通过椭圆带方法估计游泳者BSP数据的可靠性,在个人计算机屏幕上手动跟踪分段轮廓。五名评估员从11名单臂截肢游泳者的正面和侧面数字照片中数字化了地标,并追踪了身体的各个部分。五个评估员分别对每个游泳者进行了五次评估。该订单已完全随机化。在评估者内,对于所有节段的节段质心位置,对于除颈部以外的节段长度(5.2%),对于除颈部以外的节段质量(11.9%),手的变异性均小于5%(左:8.1%;右: 5.8%)和脚(左:7.3%;右:7.3%)。对评估者内部和之间的平均变异性的分析表明,评估者之间的变异性通常与评估者内部的变异性一样大或更大。因此,建议在寻求个性化的BSP数据时,最大程度地提高派生动力学的准确性和纵向和双侧受试者内部比较的敏感性,应由同一评估者对个人进行评估,并从五个重复数字化中获得平均值。这项研究建立了使用E-Zone软件的椭圆带方法是一种可靠且方便的方法,用于获取用于游泳分析的个性化BSP数据。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号