The deviation of calibration coefficients from five cup anemometer models over time was analyzed. The analysis was based on a series of laboratory calibrations between January 2001 and August 2010. The analysis was performed on two different groups of anemometers: (1) anemometers not used for any industrial purpose (that is, just stored); and (2) anemometers used in different industrial applications (mainly in the field—or outside—applications like wind farms). Results indicate a loss of performance of the studied anemometers over time. In the case of the unused anemometers the degradation shows a clear pattern. In the case of the anemometers used in the field, the data analyzed also suggest a loss of performance, yet the degradation does not show a clear trend. A recalibration schedule is proposed based on the observed performances variations
机译:分析了五个杯型风速计模型的校准系数随时间的偏差。该分析基于2001年1月至2010年8月之间的一系列实验室校准。分析是在两组不同的风速仪上进行的:(1)不用于任何工业目的(即,仅用于存储)的风速仪; (2)在不同的工业应用中使用的风速计(主要在野外或风电场等应用中使用)。结果表明,随着时间的流逝,所研究的风速计的性能有所下降。在未使用风速计的情况下,劣化表现为清晰的模式。在现场使用风速计的情况下,分析的数据也表明性能下降,但是降级并未显示出明显的趋势。根据观察到的性能变化提出重新校准时间表