首页> 外文OA文献 >Ten-year results with the Morscher press-fit cup: an uncemented, non-modular, porous-coated cup inserted without screws
【2h】

Ten-year results with the Morscher press-fit cup: an uncemented, non-modular, porous-coated cup inserted without screws

机译:Morscher压配合杯的十年效果:无水泥,无模块,多孔涂层的杯无需螺丝插入

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Total hip arthroplasty (THA) with well designed cementless acetabular implants has shown excellent results. The purpose of this study was to assess our clinical and radiological outcomes using an uncemented cup. We conducted a prospective cohort study including all consecutive primary THAs performed with the Morscher press-fit cup, an uncemented non-modular acetabular component, between March 1996 and December 1998. Patients were evaluated at ten years with clinical and radiological follow-up, patient satisfaction and questionnaire assessment using the Harris hip score (HHS), Merle d'Aubigné and Postel score, the UCLA score, the 12-item short-form health survey (SF-12) and a visual analog scale. Five hundred sixty-one THAs were performed in 518 patients. At 120 months (± 7.3 months), 303 patients with 335 THAs were still available for follow-up. None of the patients had required cup revision for aseptic loosening. At ten years, the cup survivorship was 98.8% (95% CI 97.4-99.5) with cup revision for any cause as an endpoint. No radiolucencies were seen around the cups, but osteolytic defects involved 21 stems (8.3%). Mean total linear polyethylene wear was 0.9 mm. The Morscher acetabular replacement cup provides excellent results at ten years. There were no revisions for aseptic loosening of the cup, and no osteolytic defects were found around the cup. Patient satisfaction was high and the clinical results were very good.
机译:精心设计的非骨水泥髋臼植入物的全髋关节置换术(THA)显示了出色的效果。这项研究的目的是评估使用未粘固量杯的临床和放射学结果。我们进行了一项前瞻性队列研究,包括在1996年3月至1998年12月之间使用Morscher压合杯(一种非骨水泥非模块化髋臼组件)进行的所有连续原发性THA。对患者进行了为期十年的临床和影像学随访,对患者进行了评估满意度和问卷评估,使用哈里斯(Harris)髋关节评分(HHS),梅尔·杜比涅(Merle d'Aubigné)和波斯特尔(Postel)评分,加州大学洛杉矶分校(UCLA)评分,12个项目的简短健康调查(SF-12)和视觉模拟量表。在518例患者中进行了561次THA。在120个月(±7.3个月)时,仍有335例THA的303例患者可以随访。所有患者均无需翻新杯具即可进行无菌性松动。十年后,由于任何原因导致的杯子翻修,杯子存活率为98.8%(95%CI 97.4-99.5)。杯周围未见射线透亮,但溶骨性缺损涉及21个茎(8.3%)。线性聚乙烯的平均总磨损为0.9毫米。 Morscher髋臼置换杯可在十年内提供出色的效果。没有对杯的无菌性松动进行修订,在杯周围未发现溶骨性缺陷。病人满意度很高,临床效果很好。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号