VERIFIKASI PERCENTAGE DEPTH DOSE (PDD) DAN PROFILE DOSE PESAWAT LINEAR ACCELERATOR (LINAC) BERKAS ELEKTRON 6 MeV, 9 MeV, 12 MeV DAN 15 MeV MENGGUNAKAN WATER PHANTOM

机译:使用水影验证航空器线性加速器(LINAC)电子文件的百分比深度剂量(PDD)和分布剂量的验证6 MeV,9 MeV,12 MeV和15 MeV

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

AbstrakudTelah dilakukan penelitian tentang Verifikasi Percentage Depth Dose (PDD) dan Profile Dose Pesawat Linear Accelerator (LINAC) Berkas Elektron 6 MeV, 9 MeV, 12 MeV dan 15 MeV Menggunakan Water Phantom. Penelitian ini bertujuan untuk menganalisis Percentage Depth Dose (PDD) dan Profile Dose pesawat linac jenis HCX 5640 berkas elektron 6 MeV, 9 MeV, 12 MeV dan 15 MeV untuk luas lapangan 10 x 10 cm2. Penelitian ini membandingkan data acuan yang telah ada sebelumnya dan data yang diperoleh dari hasil penelitian dengan bantuan aplikasi matrix laboratory (MATLAB) dan Microsoft Excel. udHasil penelitian menunjukkan bahwa variasi energi berkas elektron berpengaruh pada jangkauan kedalaman penyinaran, semakin besar energi elektron maka jangkauannya akan lebih dalam dibandingkan energi yang lebih kecil. Berkas elektron 6 MeV, 9 MeV, 12 MeV dan 15 MeV pada luas lapangan 10 x 10 cm2 memiliki tingkat ketidakakurasian yang bervariasi. Tingkat ketidakakurasian yang melebihi 3% tidak dapat ditolerir karena melewati standar yang ditentukan.udKata Kunci : Percentage Depth Dose (PDD), Profile Dose, Linear Accelerator,ud Water Phantom, matrix laboratory.ududABSTRACTudA research concerning verification Percentage Depth Dose (PDD) and Profile dose Linear Accelerator (LINAC) electron beam 6 MeV, 9 MeV, 12 MeV and 15 MeV using water phantom had been done. This research aims to analyze percentage depth dose (PDD) and profile dose linac HCX 5640 electron beam of 6 MeV, 9 MeV, 12 MeV and 15 MeV respectively by the field size of 10 x 10 cm2. This research compare reference data that already existed and the data that acquired from the result of the research with support by Matrix Laboratory application and Microsoft Excel.udThe results of the research showed that energy variation of electron beam impacted to depth reach of radiation, the higher electron energy had range more depth than the small electron energy. Electron beam 6 MeV, 9 MeV, 12 MeV and 15 MeV by the field size 10 x 10 cm2 has a degree of inaccuracy variated. Degree of inaccuracy that more than 3% can not be tolerated because passed the prescribed standards.udKeywords : Percentage Depth Dose (PDD), Profile Dose, Linear Accelerator, Water Phantom, Matrix Laboratory
机译:利用水体模型验证线性加速器(LINAC)电子束6 MeV,9 MeV,12 MeV和15 MeV的百分比深度剂量(PDD)和剂量分布的抽象研究。这项研究旨在分析HCX 5640直线加速器平面束电子束6 MeV,9 MeV,12 MeV和15 MeV的百分比深度剂量(PDD)和剂量分布,其场域为10 x 10 cm2。这项研究在矩阵实验室(MATLAB)和Microsoft Excel的帮助下,比较了以前的参考数据和从研究结果中获得的数据。研究结果表明,电子束能量的变化会影响辐照的深度,电子能量越大,其范围将比较小的能量更深。在10 x 10 cm2的电场区域上6 MeV,9 MeV,12 MeV和15 MeV的电子束具有不同程度的误差。超过3%的不准确度不能容忍,因为它们超出了规定的标准关键字:百分比深度剂量(PDD),轮廓剂量,线性加速器,水模,矩阵实验室。使用水体模已完成了深度剂量(PDD)和轮廓剂量线性加速器(LINAC)电子束6 MeV,9 MeV,12 MeV和15 MeV的制备。本研究旨在通过10 x 10 cm2的场大小分析6 MeV,9 MeV,12 MeV和15 MeV的百分比深度剂量(PDD)和轮廓剂量linx HCX 5640电子束。这项研究在Matrix Laboratory应用程序和Microsoft Excel的支持下,对已经存在的参考数据和从研究结果中获得的数据进行了比较,研究结果表明,电子束的能量变化会影响辐射的到达深度,高电子能量比小电子能量具有更大的深度范围。视场大小为10 x 10 cm2的电子束6 MeV,9 MeV,12 MeV和15 MeV具有变化的不精确度。 Ud关键字:百分比深度剂量(PDD),轮廓剂量,线性加速器,水模,矩阵实验室,不能接受超过3%的不准确度。

著录项

  • 作者

    Marten Padang Jumedi;

  • 作者单位
  • 年度 2015
  • 总页数
  • 原文格式 PDF
  • 正文语种 other
  • 中图分类

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号