Multi-Reader Multi-Case Studies Using the Area under the Receiver Operator Characteristic Curve as a Measure of Diagnostic Accuracy: Systematic Review with a Focus on Quality of Data Reporting.

机译:使用接收器操作员特征曲线下的面积作为诊断准确性的量度的多阅读器多案例研究:以数据报告质量为重点的系统审查。

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

INTRODUCTION: We examined the design, analysis and reporting in multi-reader multi-case (MRMC) research studies using the area under the receiver-operating curve (ROC AUC) as a measure of diagnostic performance. METHODS: We performed a systematic literature review from 2005 to 2013 inclusive to identify a minimum 50 studies. Articles of diagnostic test accuracy in humans were identified via their citation of key methodological articles dealing with MRMC ROC AUC. Two researchers in consensus then extracted information from primary articles relating to study characteristics and design, methods for reporting study outcomes, model fitting, model assumptions, presentation of results, and interpretation of findings. Results were summarized and presented with a descriptive analysis. RESULTS: Sixty-four full papers were retrieved from 475 identified citations and ultimately 49 articles describing 51 studies were reviewed and extracted. Radiological imaging was the index test in all. Most studies focused on lesion detection vs. characterization and used less than 10 readers. Only 6 (12%) studies trained readers in advance to use the confidence scale used to build the ROC curve. Overall, description of confidence scores, the ROC curve and its analysis was often incomplete. For example, 21 (41%) studies presented no ROC curve and only 3 (6%) described the distribution of confidence scores. Of 30 studies presenting curves, only 4 (13%) presented the data points underlying the curve, thereby allowing assessment of extrapolation. The mean change in AUC was 0.05 (-0.05 to 0.28). Non-significant change in AUC was attributed to underpowering rather than the diagnostic test failing to improve diagnostic accuracy. CONCLUSIONS: Data reporting in MRMC studies using ROC AUC as an outcome measure is frequently incomplete, hampering understanding of methods and the reliability of results and study conclusions. Authors using this analysis should be encouraged to provide a full description of their methods and results.
机译:简介:我们使用接收器工作曲线下的面积(ROC AUC)作为衡量诊断性能的指标,研究了多阅读器多案例(MRMC)研究中的设计,分析和报告。方法:我们从2005年至2013年进行了系统的文献综述,以鉴定至少50篇研究。通过对涉及MRMC ROC AUC的关键方法学文章的引用来鉴定对人类诊断测试准确性的文章。然后,两位研究人员达成共识,然后从主要文章中提取了有关研究特征和设计,报告研究结果的方法,模型拟合,模型假设,结果表示和结果解释的信息。总结结果并进行描述性分析。结果:从475篇已鉴定的引文中检索了64篇完整的论文,最终对描述51项研究的49篇文章进行了审查和提取。影像学检查是所有检查的指标。大多数研究都集中在病变检测与表征之间,并且使用的阅读器少于10个。只有6(12%)个研究预先训练了读者以使用用于建立ROC曲线的置信度表。总体而言,置信度得分,ROC曲线及其分析的描述通常不完整。例如,有21(41%)个研究没有显示ROC曲线,只有3个(6%)描述了置信度得分的分布。在提出曲线的30项研究中,只有4项(13%)提出了曲线下的数据点,从而可以评估外推法。 AUC的平均变化为0.05(-0.05至0.28)。 AUC的非显着变化归因于功率不足,而不是诊断测试未能提高诊断准确性。结论:使用ROC AUC作为结果衡量指标的MRMC研究中的数据报告通常不完整,这妨碍了对方法以及结果和研究结论的可靠性的理解。应该鼓励使用此分析的作者提供对其方法和结果的完整描述。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号