首页> 外文OA文献 >Changes in blood ion levels after removal of metal-on-metal hip replacements: 16 patients followed for 0-12 months.
【2h】

Changes in blood ion levels after removal of metal-on-metal hip replacements: 16 patients followed for 0-12 months.

机译:去除金属对金属髋关节置换物后血离子水平的变化:16例患者随访了0-12个月。

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

BACKGROUND AND PURPOSE: In patients with metal-on-metal (MoM) hip prostheses, pain and joint effusions may be associated with elevated blood levels of cobalt and chromium ions. Since little is known about the kinetics of metal ion clearance from the body and the rate of resolution of elevated blood ion levels, we examined the time course of cobalt and chromium ion levels after revision of MoM hip replacements. PATIENTS AND METHODS: We included 16 patients (13 female) who underwent revision of a painful MoM hip (large diameter, modern bearing) without fracture or infection, and who had a minimum of 4 blood metal ion measurements over an average period of 6.1 (0-12) months after revision. RESULTS: Average blood ion concentrations at the time of revision were 22 ppb for chromium and 43 ppb for cobalt. The change in ion levels after revision surgery varied extensively between patients. In many cases, over the second and third months after revision surgery ion levels decreased to 50% of the values measured at revision. Decay of chromium levels occurred more slowly than decay of cobalt levels, with a 9% lag in return to normal levels. The rate of decay of both metals followed second-order (exponential) kinetics more closely than first-order (linear) kinetics. INTERPRETATION: The elimination of cobalt and chromium from the blood of patients who have undergone revision of painful MoM hip arthroplasties follows an exponential decay curve with a half-life of approximately 50 days. Elevated blood levels of cobalt and chromium ions can persist for at least 1 year after revision, especially in patients with high levels of exposure.
机译:背景与目的:在金属对金属(MoM)髋关节假体患者中,疼痛和关节积液可能与钴和铬离子的血药浓度升高有关。由于对金属离子从体内清除的动力学和提高的血液离子水平的分辨率知之甚少,因此我们在修订MoM髋关节置换后检查了钴和铬离子水平的时程。患者与方法:我们纳入了16例患者(13例女性),他们接受了疼痛的MoM髋关节翻修术(大直径,现代承重),没有骨折或感染,并且在平均6.1个月内至少进行了4次血液金属离子测量(修订后的0到12个月)。结果:修订时的平均血液离子浓度铬为22 ppb,钴为43 ppb。修订手术后患者之间的离子水平变化差异很大。在许多情况下,在翻修手术后的第二个月和第三个月中,离子水平下降到翻修时测量值的50%。铬含量的下降比钴含量的下降更慢,只有9%的延迟才恢复到正常水平。两种金属的衰减速率都比一阶(线性)动力学更接近二阶(指数)动力学。解释:经历了痛苦的MoM髋关节置换术翻修的患者,血液中钴和铬的清除遵循指数衰减曲线,半衰期约为50天。翻修后,血液中钴和铬离子的升高水平可以持续至少1年,尤其是在高暴露水平患者中。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号