摘要

The MICE focusing solenoids have three 4 K coolers (two for the superconducting magnet and one for the liquid absorber) and four HTS leads that feed the current to the focusing coils. The focusing solenoids produce large radial external fields when they operate with the polarity of the two coils in opposition (the gradient or flip mode). When the MICE focusing coils operate at the same polarity (the solenoid or non-flip mode), the fields are much smaller and parallel to the axis of the solenoid. The worst-case magnetic field affects the selection of the cooler and the HTS leads. This magnetic field can also determine the height of the service towers that house the three coolers and the four HTS leads. This paper shows the criteria used for Cooler selection, HTS lead selection, and the position of both the cooler and leads with respect to the solenoid axis of rotation. © 2008 IEEE.
机译:MICE聚焦螺线管具有三个4 K冷却器(两个用于超导磁体,一个用于液体吸收器)和四个将电流馈送到聚焦线圈的HTS引线。当聚焦螺线管在两个线圈的极性相反时(梯度或翻转模式)运行时,会产生较大的径向外部磁场。当MICE聚焦线圈以相同极性操作(螺线管或非翻转模式)时,磁场会小得多,并且平行于螺线管的轴。最坏的磁场会影响冷却器和HTS引线的选择。该磁场还可以确定容纳三个冷却器和四个HTS导线的服务塔的高度。本文显示了用于选择冷却器,HTS导线的标准,以及冷却器和导线相对于螺线管旋转轴的位置。 ©2008 IEEE。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号