首页> 外文OA文献 >Validity of a new abdominal bioelectrical impedance device to measure abdominal and visceral fat: comparison with MRI.
【2h】

Validity of a new abdominal bioelectrical impedance device to measure abdominal and visceral fat: comparison with MRI.

机译:新型腹部生物电阻抗仪测量腹部和内脏脂肪的有效性:与MRI比较。

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Abdominal fat, and in particular, visceral adipose tissue (VAT), is the critical fat depot associated with metabolic aberrations. At present, VAT can only be accurately measured by computed tomography or magnetic resonance imaging (MRI). This study was designed to compare a new abdominal bioelectrical impedance (BIA) device against total abdominal adipose tissue (TAAT) and VAT area measurements made from an abdominal MRI scan, and to assess its reliability and accuracy. One-hundred twenty participants were recruited, stratified by gender and BMI. Participants had triplicate measures of abdominal fat and waist circumference (WC) with the AB-140 (Tanita, Tokyo, Japan) and WC measurements using a manual tape measure. A single abdominal MRI scan was performed as the reference method. Triplicate measures with the AB-140 showed excellent precision for "visceral fat level," trunk fat %, and WC. AB-140 "visceral fat level" showed significantly stronger correlations with MRI TAAT area than with MRI VAT area (r = 0.94 vs. 0.65 in men and 0.92 vs. 0.64 in women). AB-140 WC showed good correlation with manual WC measurements (r = 0.95 in men and 0.90 in women). AB-140 and manual WCs showed comparable correlations with MRI TAAT area (r = 0.92 and 0.96 in men and 0.88 and 0.88 in women). AB-140 is a simple, quick, and precise technique to measure abdominal fat and WC in healthy adults. It provides a useful proxy for TAAT measured by MRI, comparable to the correlation obtained with manual WC measurements. Neither the AB-140 abdominal fat measures nor WC measurement appear to provide a useful proxy measure of VAT.
机译:腹部脂肪,尤其是内脏脂肪组织(VAT),是与代谢异常相关的关键脂肪储库。目前,增值税只能通过计算机断层扫描或磁共振成像(MRI)进行准确测量。这项研究的目的是将新型腹部生物电阻抗(BIA)设备与通过腹部MRI扫描进行的总腹部脂肪组织(TAAT)和VAT面积测量进行比较,并评估其可靠性和准确性。招募了一百二十名参与者,按性别和BMI进行了分层。参与者使用AB-140(日本东京都田田市)对腹部脂肪和腰围(WC)进行了三次重复测量,并使用手动卷尺进行了WC测量。作为参考方法,进行了一次腹部MRI扫描。 AB-140一式三份的测量结果显示“内脏脂肪水平”,躯干脂肪%和WC的精确度很高。与MRI VAT区域相比,AB-140“内脏脂肪水平”与MRI TAAT区域的相关性显着增强(男性= 0.94 vs. 0.65,女性为0.92 vs. 0.64)。 AB-140 WC与手动WC测量显示出良好的相关性(男性r = 0.95,女性r = 0.90)。 AB-140和手动WC与MRI TAAT面积具有可比的相关性(男性r = 0.92和0.96,女性r = 0.88和0.88)。 AB-140是一种简单,快速,精确的技术,可以测量健康成年人的腹部脂肪和WC。与通过手动WC测量获得的相关性相比,它为MRI测量的TAAT提供了有用的代理。 AB-140腹部脂肪测量值和WC测量值都不能提供有用的增值税替代指标。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号