首页> 外文OA文献 >Comparison of microleakage in Class II cavities restored with silorane-based and methacrylate-based composite resins using different restorative techniques over time.
【2h】

Comparison of microleakage in Class II cavities restored with silorane-based and methacrylate-based composite resins using different restorative techniques over time.

机译:随时间推移,使用不同的修复技术,用硅氧烷基和甲基丙烯酸酯基复合树脂修复的II类腔体中的微渗漏的比较。

摘要

BACKGROUNDududDespite the growing tendency toward tooth-colored restorations in dentistry, polymerization shrinkage and subsequent marginal microleakage remains a problem. The aim of this in vitro study was to compare microleakage between silorane-based and methacrylate-based composite resins at different time intervals and with different restorative techniques.ududMATERIALS AND METHODSududIn this in vitro study, 108 sound extracted human molar teeth were used. Mesial and distal proximal class II boxes with dimensions of 1.5 mm depth and 4 mm width were prepared. The gingival margins of all cavities were 1 mm below the cement enamel junction. The teeth were randomly divided into three groups based on test materials. In the first group, the teeth were restored by a nanocomposite (Filtek Z350XT, 3MESPE) and SE Bond adhesive (Kuraray, Japan), in the second group, the teeth were restored with a silorane-based (Filtek P90, 3MESPE) and Filtek P90 Adhesive (3M ESPE, USA) and in the third group, the teeth were restored with a microhybrid posterior composite resin (Filtek P60, 3MESPE) and SE Bond adhesive (Kuraray, Japan). Half of the proximal cavities in each of these three groups were restored in two horizontal layers and the other half in four horizontal layers. After a period of aging (24-h, 3-month and 6-month) in water and then application of 500 thermal cycles, the teeth were immersed for 24-h in 0.5% fuchsin and evaluated under a stereomicroscope at ×36 magnification to evaluate leakage in gingival margin. Data was statistically analyzed using Kruskal-Wallis and Mann-Whitney U-tests. P ≤ 0.05 was considered as significant.ududRESULTSududIn Z350XT statistically significant differences were observed in microleakage in comparison of 24-h and 6-month intervals (P = 0.01) that was higher in 6-month. Comparison of microleakage in P90 and P60 composite resins was also statistically significant and was less in P90. Microleakage was not significantly different between P90 and Z350XT at 24-h. However, this difference was significant at 3-month and 6-month intervals. Differences in microleakage of P60 and Z-350XT composite resins were not statistically significant in all intervals (P = 0.38). P90 showed the lowest microleakage during storage in water. Z350XT had microleakage similar to P90 within 24-h, but after 6-month of storage in water, it showed the highest microleakage among all the groups. The number of layers (2 layers vs. 4 layers) did not result in any differences in microleakage scores of the composite resins (P = 0.42).ududCONCLUSIONududWater storage times did not result in any significant effect on microleakage of P90 and P60.
机译:背景技术尽管在牙科领域中牙齿着色修复体的增长趋势越来越大,但是聚合收缩和随后的边缘微渗漏仍然是一个问题。这项体外研究的目的是比较在不同时间间隔和采用不同修复技术的硅氧烷基和甲基丙烯酸酯基复合树脂之间的微渗漏。 ud ud材料和方法 ud ud使用磨牙。准备尺寸为1.5毫米深度和4毫米宽度的中,近端II类近端盒子。所有腔的牙龈边缘在水泥釉质接合处以下1 mm。根据测试材料将牙齿随机分为三组。在第一组中,用纳米复合材料(Filtek Z350XT,3MESPE)和SE Bond胶粘剂(日本可乐丽)来修复牙齿,在第二组中,用硅氧烷(Filtek P90,3MESPE)和Filtek修复牙齿。 P90粘合剂(美国3M ESPE),第三组使用微混合后路复合树脂(Filtek P60,3MESPE)和SE Bond粘合剂(日本可乐丽)修复牙齿。这三组中的近端腔的一半在两个水平层中恢复,另一半在四个水平层中恢复。在水中经过一段时间的老化(24小时,3个月和6个月),然后进行500次热循环后,将牙齿浸入0.5%品红中24小时,并在立体显微镜下以×36的倍率进行评估,评估牙龈边缘的渗漏。使用Kruskal-Wallis和Mann-Whitney U检验对数据进行统计分析。 P≤0.05被认为是显着的。 ud udRESULTS ud ud在Z350XT中,与24小时和6个月间隔相比,微渗漏在统计学上具有显着差异(P = 0.01),在6个月时更高。 P90和P60复合树脂中微渗漏的比较也具有统计学意义,而P90中的渗漏较少。 P90和Z350XT在24小时之间的微渗漏没有显着差异。但是,这种差异在3个月和6个月的时间间隔内很明显。 P60和Z-350XT复合树脂的微渗漏差异在所有间隔中均无统计学意义(P = 0.38)。 P90在水中储存期间显示出最低的微泄漏。 Z350XT在24小时内具有与P90相似的微渗漏,但在水中储存6个月后,它显示出所有组中最高的微渗漏。层数(2层对比4层)对复合树脂的微渗漏评分没有任何差异(P = 0.42)。 ud ud结论 ud ud储水时间对微渗漏没有显着影响P90和P60。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号