Wound Rotor Induction Generator With Sensorless Control and Integrated Active Filter for Feeding Nonlinear Loads in a Stand-Alone Grid

机译:带有无传感器控制和集成有源滤波器的绕线转子感应发电机,用于为独立电网提供非线性负载

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

This paper describes a vector control scheme for a stand-alone generator based on a wound rotor induction machine with rotor side control. The stand-alone generator refers to an isolated grid feeding a local load. The primary objective of the control scheme is to maintain constant voltage and frequency at the output of the generator irrespective of prime mover speed variation. A novel, simple, and easily implementable sensorless control scheme is proposed. The issue of power quality, which is one of the main concerns of a stand-alone generation system, is also addressed. This is done by incorporating the active filter concept in the control scheme to cancel significant harmonics. A method of unit vector generation for field-oriented control is proposed. A laboratory prototype consisting of back-to-back insulated-gate bipolar transistor converters and a TMS320F240 DSP controller is developed. Detailed experimental results are presented which demonstrate and validate the effectiveness of the proposed scheme.
机译:本文介绍了一种基于带有转子侧控制的绕线式转子感应电机的独立发电机的矢量控制方案。独立发电机是指为本地负载供电的隔离电网。控制方案的主要目标是与原动机速度变化无关,在发电机的输出端保持恒定的电压和频率。提出了一种新颖,简单,易于实现的无传感器控制方案。还解决了电能质量问题,这是独立发电系统的主要问题之一。这是通过在控制方案中加入有源滤波器概念来消除明显的谐波来完成的。提出了一种用于磁场定向控制的单位矢量生成方法。开发了一个由背靠背绝缘栅双极型晶体管转换器和TMS320F240 DSP控制器组成的实验室原型。给出了详细的实验结果,这些结果证明并验证了所提出方案的有效性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号