Aplikasi sistem perolehan semula tenaga udara-ke-udara sebagai salah satuudteknologi cekap tenaga yang membantu sistem penghawa dingin tradisional dalamudbangunan telah mendapat perhatian sejak kebelakangan ini kerana potensinya dalamudpenjimatan tenaga. Sistem perolehan semula tenaga udara-ke-udara yang direka dalamudkajian ini menggunakan jenis plat tetap yang diperbuat daripada membran polimerudhidrofilik dan dilengkapi dengan konfigurasi aliran silang untuk membantu penghawauddingin. Matlamat utama kajian ini adalah untuk mengkaji prestasi sistem perolehanudsemula tenaga udara-ke-udara berdasarkan keadaan cuaca di luar yang telah direkaudserta data cuaca yang dikumpul berdasarkan persekitaran panas-lembap. Sebuahudkemudahan eksperimen telah direka bentuk untuk menghasilkan semula persekitaranudpanas lembap yang biasa dalam keadaan udara di luar dan dalam bangunan berkaituddengan suhu serta kelembapan relatif. Unit ini kemudiannya diuji di bawah syaratsyaratudoperasi yang seimbang, yang lazimnya digunakan dalam aplikasi. Padaudbahagian pertama, pengaruh parameter seperti aliran udara pada (1.0 hingga 3.0 m/s),udsuhu udara pada (28°C, 31°C, 35°C dan 40°C) serta kelembapan relatif pada (70%,ud75%, 80%, 85% dan 90%) telah diuji di bawah keadaan berbeza bagi mengkaji prestasiudsistem tersebut.ududApplication of an air-to-air energy recovery system as one of the energyudefficient technologies that assists with the traditional HVAC system in buildingudapplication has gained recent attention because of its potential for energy savings. Theudair-to-air energy recovery system developed in this study employs a fixed plate typeudof air-to-air energy recovery system made up of hydrophilic polymeric membraneudequipped with cross flow configuration designed to assist air-conditioning. Theudprimary goal of this study is to investigate the air-to-air energy recovery system’sudperformance based on the outdoor design air-condition and real weather data collectedudwith respect to the hot-humid environment. An experimental facility was designed toudreproduce the chosen typical hot-humid environment in outdoor and indoor airudconditions with respect to temperature and relative humidity. Next, the system wasudtested under stable operation conditions as frequently used in practice. For the firstudpart, the operating parameters which are airflow rates of (1.0 to 3.0 m/s), intake airudtemperature of (28°C, 31°C, 35°C and 40°C) and intake relative humidity of (70%,ud75%, 80%, 85% and 90%) were varied under certain air conditions to investigate theudsystem’s performance.
机译:空气对空气回收系统作为帮助建筑物中传统空调系统的节能技术之一,由于其在节能方面的潜力,近来受到关注。本研究中设计的空对空回收系统使用一种由聚合物膜制成的固定板,并配有横流配置以辅助空调。这项研究的主要目的是根据已设计的天气条件和基于湿热环境收集的天气数据来研究空对空能源回收系统的性能。设计了一个实验系统,以在室外和室内空气条件下再现与温度和相对湿度有关的常见潮湿环境。然后在平衡操作条件下对本机进行测试,该操作通常在应用中使用。在第一部分中,参数的影响如(1.0至3.0 m / s时的气流,(28°C,31°C,35°C和40°C)的湿度和(70%, ud75%,80%,85%和90%)已在不同条件下进行了测试,以研究系统的性能。 ud ud空对空能量回收系统的应用是一种能源效率高的技术,可帮助传统的建筑暖通空调系统由于其节能潜力而受到了最近的关注。本研究开发的udair-to-空气能量回收系统采用固定板式udof空气-空气能量回收系统,该系统由亲水性聚合物膜制成,配备有横流配置,旨在辅助空调。这项研究的首要目标是根据室外设计的空调情况和收集到的有关湿热环境的实际天气数据来研究空对空能量回收系统的性能。设计了一个实验设备,以在温度和相对湿度的条件下在室外和室内空气中复制所选的典型热湿环境。接下来,在实际操作中经常使用的稳定运行条件下对该系统进行了测试。对于第一个部分,运行参数为(1.0至3.0 m / s的气流速率),(28°C,31°C,35°C和40°C的)进气温度和进气的相对湿度。 (70%,ud75%,80%,85%和90%)在某些空气条件下进行了变化,以研究udsystem的性能。

著录项

  • 作者

    Mansur Fatin Zafirah;

  • 作者单位
  • 年度 2016
  • 总页数
  • 原文格式 PDF
  • 正文语种
  • 中图分类

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号