首页> 外文OA文献 >iPod-based in-home system for monitoring gaze-stabilization exercise compliance of individuals with vestibular hypofunction.
【2h】

iPod-based in-home system for monitoring gaze-stabilization exercise compliance of individuals with vestibular hypofunction.

机译:基于iPod的家庭系统,用于监视具有前庭功能减退的个体的注视稳定运动依从性。

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

BACKGROUND: In the physical therapy setting, physical therapists (PTs) often prescribe exercises for their clients to perform at home. However, it is difficult for PTs to obtain information about their clients\u27 compliance with the prescribed exercises, the quality of performance and symptom magnitude. We present an iPod-based system for capturing this information from individuals with vestibular hypofunction while they perform gaze stabilization exercises at home.METHOD: The system\u27s accuracy for measurement of rotational velocity against an independent motion tracker was validated. Then a seven day in-home trial was conducted with 10 individuals to assess the feasibility of implementing the system. Compliance was measured by comparing the recorded frequency and duration of the exercises with the exercise prescription. The velocity and range of motion of head movements was recorded in the pitch and yaw planes. The system also recorded dizziness severity before and after each exercise was performed. Each patient was interviewed briefly after the trial to ascertain ease of use. In addition, an interview was performed with PTs in order to assess how the information would be utilized.RESULTS: The correlation of the velocity measurements between the iPod-based system and the motion tracker was 0.99. Half of the subjects were under-compliant with the prescribed exercises. The average head velocity during performance was 140 deg/s in the yaw plane and 101 deg/s in the pitch plane.CONCLUSIONS: The iPod-based system was able to be used in-home. Interviews with PTs suggest that the quantitative data from the system will be valuable for assisting PTs in understanding exercise performance of patients, documenting progress, making treatment decisions, and communicating patient status to other PTs.
机译:背景:在物理治疗环境中,物理治疗师(PT)经常会为其客户开一些练习,让他们在家中进行表演。但是,PT很难获得有关其客户是否遵守规定的锻炼,行为质量和症状严重程度的信息。我们提出了一种基于iPod的系统,该系统可在有前庭功能低下的人在家中进行稳定注视运动时捕获这些信息。方法:验证了该系统针对独立运动跟踪器测量旋转速度的准确性。然后,与10个人进行了为期7天的家庭试用,以评估实施该系统的可行性。通过将记录的运动频率和持续时间与运动处方进行比较来测量依从性。在俯仰和偏航平面上记录头部运动的速度和范围。该系统还记录了每次运动前后的头晕严重程度。试验后对每位患者进行了简短访谈,以确定其易用性。此外,还对PT进行了访谈,以评估信息的利用方式。结果:基于iPod的系统与运动跟踪器之间的速度测量值之间的相关性为0.99。一半的受试者未按规定进行锻炼。在演奏过程中,平均头速度在偏航平面中为140度/秒,在俯仰平面中为101度/秒。结论:基于iPod的系统可以在家中使用。与PT进行的访谈表明,系统中的定量数据对于帮助PT了解患者的运动表现,记录进展情况,制定治疗决策以及将患者的状况传达给其他PT具有宝贵的价值。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号