摘要

A low argon flow torch has been developed for axially viewed ICP-AES. Outer argon flow has been drastically reduced (less than 7 L min-1 ) by cooling the torch wall with air passing through a cooling jacket added to the outside of a Fassel torch. The plasma is viewed axially through a cooled cone interface centered on the axial channel. Although detection limits (DL) for lines at ~200 nm are poorer by about a factor of two, those for lines at ~400 nm are actually much better than values typically seen for the same lines by axial viewing of a conventional, high-flow ICP.;Silicon measurement at m/z 28, 29 and 30 by ICP-MS is complicated by the spectral interferences caused by organic molecular ions, nitrogen and nitrogen oxides. A method has been developed to measure silicon in organic solvents by reducing polyatomic interferences at m/z 28 to 30 using cryogenic desolvation for removal of organic solvent from the wet droplets in aerosol, and by adding krypton or xenon to the sample gas flow of plasma. Isotope ratios can be measured by medium resolution (R = 4000) ICP-MS by direct nebulization of organic solvents. To avoid deposition on the interface cone, the flow of oxygen in the spray chamber is adjusted to titrate carbon in the plasma. Despite the sharply pointed peaks at R = 4000, ratio precision of +/-0.1% RSD can be obtained using approximately 1 mug of silicon.;Electrochemically modulated liquid chromatography (EMLC) column has been adapted online with ICP-MS to clean up blanks to reduce background signals. Metal ions can be retained from the flow of blanks in the micrometer size glassy carbon particle packing with appropriate negative potential. A Ag/AgCl (satd. NaCl) reference electrode in dilute nitric acid supporting electrolyte was used for electrochemical cell combination. Several metal ions have found to be retained with \u3e99% extraction efficiency from the blank solution. Cleaning of the column can be done easily by stripping the deposited metal with a high positive potential.
机译:已开发出一种低氩气流炬,用于轴向观察ICP-AES。通过使用通过流经Fassel火炬外部的冷却套的空气冷却炬管壁,已大大减少了外部氩气流(小于7 L min-1)。通过以轴向通道为中心的冷却锥界面轴向查看等离子体。尽管〜200 nm处的检测限(DL)差了大约两倍,但〜400 nm处的检测限实际上要比通过轴向观察常规高流量样品所见的检测限好得多。 ICP .; ICP-MS在m / z 28、29和30下对硅的测量由于有机分子离子,氮和氮氧化物引起的光谱干扰而变得复杂。已开发出一种方法,通过使用低温去溶剂化法从气溶胶中的湿滴中去除有机溶剂,并在血浆样品气流中添加k或氙,从而将m / z 28至30时的多原子干扰降低到有机溶剂中,从而测量硅。同位素比可以通过中度分辨率(R = 4000)ICP-MS通过直接雾化有机溶剂来测量。为避免沉积在界面锥上,调节喷雾室中的氧气流量以滴定等离子体中的碳。尽管在R = 4000处出现了尖锐的峰,但使用约1杯硅可以得到比率精度+/- 0.1%RSD .;电化学调制液相色谱(EMLC)色谱柱已在ICP-MS上进行在线调整以清除空白减少背景信号。金属离子可以从毛坯中以适当的负电位保留在微米级玻璃碳颗粒填料中。稀硝酸支持电解质中的Ag / AgCl(饱和NaCl)参比电极用于电化学电池组合。已发现保留了几种金属离子,空白溶液中的金属离子的提取效率约为99%。通过汽提高正电位的沉积金属可以轻松完成色谱柱的清洁。

著录项

  • 作者

    Hasan, Towhid;

  • 作者单位
  • 年度 2001
  • 总页数
  • 原文格式 PDF
  • 正文语种 en
  • 中图分类

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号