首页> 外文OA文献 >Use of CO 2 Concentrations or CO 2 Balance to Estimate Ventilation Rate of Modern Commercial Broiler Houses
【2h】

Use of CO 2 Concentrations or CO 2 Balance to Estimate Ventilation Rate of Modern Commercial Broiler Houses

机译:使用CO 2浓度或CO 2平衡来估算现代商业肉鸡舍的通风率

摘要

Ventilation rate (VR) is one of the two key elements for quantifying aerial emissions from animal production facilities. Direct measurement of building VR can be challenging and impractical under certain circumstances, e.g., naturally ventilated animal housing. This study delineates VR of broiler houses with build-up litter as estimated via CO2 balance or building CO2 concentration. The indirectly derived VR compared favorably with the directly measured VR. Specifically, integration time of 30 min or longer leads to non-significant differences in VR between the indirect and the direct methods (Pu3e0.2). Omission of CO2 generation by the litter from total house CO2 production results in an overall 7% underestimation of the building VR. The indirect method provides a possible, viable alternative for quantifying VR of naturally ventilated broiler confinement.
机译:通风率(VR)是量化动物生产设施空中排放的两个关键要素之一。在某些情况下,例如自然通风的动物住房,直接测量建筑物的VR可能具有挑战性和不切实际。这项研究描述了通过二氧化碳平衡或建筑物中二氧化碳浓度估算的堆积鸡窝的VR。间接导出的VR优于直接测量的VR。具体而言,积分时间为30分钟或更长时间会导致间接方法和直接方法之间的VR差异不显着(P u3e0.2)。房屋总CO2产生的垃圾所产生的CO2的遗漏会导致建筑物VR的总体低估7%。间接方法为定量自然通风的肉鸡禁闭区的VR提供了一种可能的可行替代方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号