首页> 外文OA文献 >Energy comparison of under floor air distribution heating ventilation and air conditioning systems in office buildings
【2h】

Energy comparison of under floor air distribution heating ventilation and air conditioning systems in office buildings

机译:办公楼地下空气分配采暖通风和空调系统的能量比较

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The purpose of this paper is to compare energy consumption with under floor air distribution systems for office buildings, specifically a call center application.;The building being modeled will have an HVAC system that utilizes an underfloor air distribution system (UFAD). This type of system allows air to be introduced into the plenum space under the floor. The air comes up through the floor into the space through plenum space pressurization. The air is then taken out of the space up high and returned back to the air handling unit.;The three systems reviewed for delivery of the air to the underfloor system (comparing energy consumption on the UFAD systems) are roof top units (RTU) with full economizers, boilers and chillers and a ground source heat pump (GSHP). These systems are being modeled as a heating and cooling plant for the UFAD system. The first costs as well as the energy consumption have been analyzed to determine simple paybacks from system to system listed above.;It was calculated that the RTU has the lowest initial cost at {dollar}1,492,049, the boiler/chiller was next at {dollar}1,769,069 and the highest cost system was the GSHP at {dollar}2,700,002. The systems energy cost per year were calculated to be; RTU - {dollar}77,440, boiler/chiller - {dollar}46,782 and GSHP - {dollar}8,557. The system paybacks from the RTU versus the boiler/chiller were 9 years, the RTU versus the GSHP was 17.4 years and the boiler/chiller versus the GSHP was 24 years.
机译:本文的目的是将能耗与办公大楼的地板下空气分配系统(特别是呼叫中心应用)进行比较。;正在建模的建筑物将具有一个采用地板下空气分配系统(UFAD)的HVAC系统。这种类型的系统允许将空气引入地板下的通风空间。空气通过增压空间从地板上升进入空间。然后将空气从较高的空间中抽出,然后返回到空气处理单元。审查过的用于将空气输送到地板下系统(比较UFAD系统的能耗)的三个系统是屋顶单元(RTU)配备完整的省煤器,锅炉和冷水机组以及地源热泵(GSHP)。这些系统被建模为UFAD系统的加热和冷却设备。分析了最初的成本和能耗,以确定上面列出的系统之间的简单投资回收期;据计算,RTU的初始成本最低,为$ 1,492,049,锅炉/冷风机为第二,最低为{dollar} } 1,769,069,而成本最高的系统是GSHP,金额为{700,002}。每年的系统能源成本经计算为: RTU-{$ 74,440,锅炉/冷却器-$ 46,782,GSHP-$ 8,557。 RTU对锅炉/冷水机的系统投资回收期为9年,RTU对GSHP的为17.4年,锅炉/制冷机对GSHP的为24年。

著录项

  • 作者

    Giles, Jonathon Richard;

  • 作者单位
  • 年度 2008
  • 总页数
  • 原文格式 PDF
  • 正文语种 en
  • 中图分类
  • 入库时间 2022-08-20 20:23:42

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号