Heat transfer evaluation of HFC-236ea and HFC-236fa in evaporation and condensation

机译:HFC-236ea和HFC-236fa在蒸发和冷凝中的传热评估

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

This research evaluated the shell-side heat transfer coefficients of HFC-236ea and HFC-236fa, which are environment-safe and considered as prospective substitutes for replacing CFC-114 in Navy shipboard chillers;Work has been performed on two types of low integral-fin tubes (1024-fpm and 1575-fpm tubes) and three types of high performance enhanced tubes (Turbo-CII, Turbo-B, and Turbo-BII tubes). HFC-236fa was tested with these five tubes during pool boiling and condensation, while HFC-236ea was tested mainly with the three high performance enhanced tubes during pool boiling, spray evaporation, and condensation;Measurements were conducted on a single-tube configuration at a saturation temperature of 2°C for pool boiling as well as spray evaporation and at 40°C for condensation. The tubes which have nominal outer diameters of 3/4 inch (19.1 mm) were tested from 15 kW/m2 to 40 kW/m2 for both pool boiling and condensation, and 10 kW/m2 to 30 kW/m2 for spray evaporation;The high performance enhanced tubes were found to effectively enhance heat transfer and produced higher heat transfer coefficients than the integral-fin tubes for both HFC-236ea and HFC-236fa during either pool boiling or condensation;Shell-side heat transfer coefficients of HFC-236fa, HFC-236ea, and CFC-114 were compared with each other. In general, HFC-236fa had higher heat transfer coefficients than CFC-114 and HFC-236ea during both pool boiling and condensation;The comparative heat transfer performance of spray evaporation with pool boiling was made for HFC-236ea by using a Turbo-B tube and a 1575-fpm tube. For the range of liquid refrigerant feed rates evaluated, the superiority of spray evaporation over pool boiling was found to exist only at the heat fluxes below the approximate value of 30 kW/m2.;The effects of compressor oil on heat transfer performance during pool boiling were investigated. The presence of up to 3% oil in HFC-236fa affected the boiling performance by less than 10% from the pure HFC-236fa value for all the tubes tested except the Turbo-BII tube.
机译:这项研究评估了HFC-236ea和HFC-236fa的壳侧传热系数,它们对环境安全,被认为是替代海军舰载冷水机组中CFC-114的潜在替代品;已经对两种类型的低整体制冷剂进行了研究,翅片管(1024-fpm和1575-fpm的管)和三种类型的高性能增强管(Turbo-CII,Turbo-B和Turbo-BII管)。 HFC-236fa在池沸腾和冷凝过程中用这五个管进行了测试,而HFC-236ea主要在池沸腾,喷雾蒸发和冷凝过程中用了三个高性能增强管进行了测试;测量是在单管配置下进行的。池沸腾和喷雾蒸发的饱和温度为2°C,冷凝时的饱和温度为40°C。标称外径为3/4英寸(19.1毫米)的管子在池沸腾和冷凝中从15 kW / m2到40 kW / m2进行了测试,对于喷雾蒸发从10 kW / m2到30 kW / m2进行了测试;发现在池沸腾或冷凝过程中,对于HFC-236ea和HFC-236fa,高性能增强管可有效增强传热,并产生比整体翅片管更高的传热系数; HFC-236fa的壳侧传热系数将HFC-236ea和CFC-114进行了比较。通常,在池沸腾和冷凝过程中,HFC-236fa的传热系数均高于CFC-114和HFC-236ea;使用Turbo-B管对HFC-236ea进行了具有池沸腾的喷雾蒸发的比较传热性能和1575-fpm的灯管在所评估的液体制冷剂进料速率范围内,仅在低于约30 kW / m2的热通量时才发现喷雾蒸发优于池沸腾。;压缩机油对池沸腾过程中传热性能的影响被调查了。在所有HFC-236fa中,除了Turbo-BII管外,所有油管中的最高3%的油影响其纯HFC-236fa值的沸腾性能不到10%。

著录项

  • 作者

    Tzuoo, Shin-Miin;

  • 作者单位
  • 年度 1997
  • 总页数
  • 原文格式 PDF
  • 正文语种 en
  • 中图分类

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号