首页> 外文OA文献 >Agreement between arterial partial pressure of carbon dioxide and saturation of hemoglobin with oxygen values obtained by direct arterial blood measurements versus noninvasive methods in conscious healthy and ill foals
【2h】

Agreement between arterial partial pressure of carbon dioxide and saturation of hemoglobin with oxygen values obtained by direct arterial blood measurements versus noninvasive methods in conscious healthy and ill foals

机译:在有意识的健康和患病小马驹中,通过直接动脉血测量与非侵入性方法获得的二氧化碳动脉分压和血红蛋白饱和度与氧气值之间的一致性

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Objective—To determine agreement between indirect measurements of end-tidal partial pressure of carbon dioxide (Petco2) and saturation of hemoglobin with oxygen as measured by pulse oximetry (Spo2) with direct measurements of Paco2 and calculated saturation of hemoglobin with oxygen in arterial blood (Sao2) in conscious healthy and ill foals. Design—Validation study. Animals—10 healthy and 21 ill neonatal foals. Procedures—Arterial blood gas analysis was performed on healthy and ill foals examined at a veterinary teaching hospital to determine direct measurements of Paco2 and Pao2 along with Sao2. Concurrently, Petco2 was measured with a capnograph inserted into a naris, and Spo2 was measured with a reflectance probe placed at the base of the tail. Paired values were compared by use of Pearson correlation coefficients, and level of agreement was assessed with the Bland-Altman method. Results—Mean ± SD difference between Paco2 and Petco2 was 0.1 ± 5.0 mm Hg. There was significant strong correlation (r = 0.779) and good agreement between Paco2 and Petco2. Mean ± SD difference between Sao2 and Spo2 was 2.5 ± 3.5%. There was significant moderate correlation (r = 0.499) and acceptable agreement between Sao2 and Spo2. Conclusions and Clinical Relevance—Both Petco2 obtained by use of nasal capnography and Spo2 obtained with a reflectance probe are clinically applicable and accurate indirect methods of estimating and monitoring Paco2 and Sao2 in neonatal foals. Indirect methods should not replace periodic direct measurement of corresponding parameters.
机译:目的-确定直接测量Paco2的脉搏血氧饱和度(Spo2)和脉搏血氧饱和度(Spo2)间接测量的潮气末二氧化碳分压(Petco2)与血红蛋白含氧饱和度和计算得出的动脉血中血红蛋白与氧饱和度之间的一致性( Sao2)在有意识的健康和生病的小马驹中。设计—验证研究。动物-10只健康的小动物和21只病的新生儿小马驹。程序-在兽医教学医院对健康和患病的小马驹进行动脉血气分析,以确定Paco2和Pao2以及Sao2的直接测量值。同时,用二氧化碳分析仪在鼻孔中插入Petco2进行测量,并用位于尾巴底部的反射探针测量Spo2。使用Pearson相关系数比较配对值,并使用Bland-Altman方法评估一致性水平。结果-Paco2和Petco2之间的平均值±SD差为0.1±5.0毫米汞柱。 Paco2和Petco2之间存在显着的强相关性(r = 0.779)和良好的一致性。 Sao2和Spo2之间的平均值±SD差异为2.5±3.5%。 Sao2和Spo2之间存在显着的中等相关性(r = 0.499),并且可以接受。结论与临床意义-通过鼻内二氧化碳图获得的Petco2和通过反射探头获得的Spo2都是临床适用的,准确的间接方法,用于评估和监测新生儿马驹中的Paco2和Sao2。间接方法不应替代定期直接测量相应参数的方法。