Desalination unit based on heat pump with humidification anduddehumidification processes is one of the applications of heat pump system, withudaddition of a humidifier, sprinkler and evaporator (as dehumidifier) that integratedudin a duct. The air has humidified in the humidifier with the spray of seawaterudthrough the sprinkler and then it has cooled in the evaporator to produce freshudwater. The addition of electric water heater has used to vary the seawaterudtemperature to the humidifier on this system. In this research has examined theudeffect of preheating seawater temperature on the performance of desalination unitudbased on heat pump system with using humidification and dehumidificationudprocesses. In this research the seawater/feed water temperature has varied at 28oC,ud30oC, 45oC and 60oC, air temperature has conditioned at a constant temperature ofud30oC, and ambient temperature has kept constant at 28oC. Compressor hasudoperated at a constant rotation of 1,200 rpm, the seawater volumetric flow rate hasudkept at 300 l/h, and seawater in this system has recirculated. The result of thisudresearch showed that the volume of fresh water production increase withudincreasing the inlet of the seawater/feed water temperature to the humidifier onudthis desalination unit.ududKeywords : desalination, heat pump, preheating, humidification, dehumidificationud
机译:基于热泵的加湿和除湿工艺的脱盐装置是热泵系统的应用之一,其中加湿器,喷头和蒸发器(作为除湿器)集成在管道中。空气在加湿器中被海水喷雾通过喷头加湿,然后在蒸发器中冷却以产生淡水。电热水器的添加已用来改变该系统上加湿器的海水温度。本研究以加湿除湿的热泵系统为基础,研究了预热海水温度对海水淡化装置性能的影响。在这项研究中,海水/给水温度在28oC,ud30oC,45oC和60oC之间变化,空气温度调节在ud30oC恒定温度,环境温度在28oC保持恒定。压缩机以1200 rpm的恒定转速运转,海水体积流量保持在300 l / h,并且该系统中的海水已经再循环。这项研究的结果表明,该淡化装置上加湿器的海水/给水温度入口的增加,使淡水生产量增加了。ud关键词:脱盐,热泵,预热,加湿,除湿 ud

著录项

  • 作者

    ANDRIYANTO TOMI;

  • 作者单位
  • 年度 2011
  • 总页数
  • 原文格式 PDF
  • 正文语种 {"code":"id","name":"Indonesian","id":20}
  • 中图分类

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号