Punching strength is a critical point in the design of flat slabs and due to the lack of a theoretical method capable of explaining this phenomenon, empirical formulations presented by codes of practice are still the most used method to check the bearing capacity of slab-column connections. This paper discusses relevant aspects of the development of flat slabs, the factors that influence the punching resistance of slabs without shear reinforcement and makes comparisons between the experimental results organized in a database with 74 slabs carefully selected with theoretical results using the recommendations of ACI 318, EUROCODE 2 and NBR 6118 and also through the Critical Shear Crack Theory, presented by Muttoni (2008) and incorporated the new fib Model Code (2010).
机译:冲压强度是平板设计的关键点,由于缺乏能够解释这种现象的理论方法,实践准则提出的经验公式仍然是检查平板-柱连接承载力的最常用方法。 。本文讨论了平板开发的相关方面,影响不带剪切补强的平板的抗冲孔性的因素,并根据ACI 318的建议,对数据库中组织的74个平板的实验结果与理论结果进行了仔细比较,并与理论结果进行了比较, EUROCODE 2和NBR 6118以及通过Muttoni(2008)提出的临界剪切裂纹理论,并结合了新的fib模型代码(2010)。