首页> 外文OA文献 >Estimate of the shielding effectiveness of an electrically large enclosure made with pierced metallic plate in a well-stirred reverberation chamber
【2h】

Estimate of the shielding effectiveness of an electrically large enclosure made with pierced metallic plate in a well-stirred reverberation chamber

机译:估算在良好搅拌的混响室内用穿孔金属板制成的大型电气外壳的屏蔽效果

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

In this document, a simple and efficacious method to estimate the shielding effectiveness of an electrically large enclosure (SEe) made with pierced metallic plate is shown under uniform and isotropic field conditions, which are produced in a reverberation chamber (RC) where the field is well stirred. The estimate is made by the calculation of the transmission cross sections (TCSs) of the walls of an enclosure and absorption cross sections (ACSs) of the inner losses. TCSs and ACSs are connected to the shielding effectiveness (SE) of the walls and inner losses, respectively; the latter are also connected to the reflectivity of the enclosure internal walls. The comparison with measurements made in an RC matches enough. It shows that the method shown here is sound. Moreover, the results support a recent model that connects SEe to SE by the reflectivity of the enclosure internal walls, and show still further that unloaded electrically large enclosures with distributed apertures are not very efficacious.
机译:在本文档中,展示了一种简单有效的方法,用于估计在均匀且各向同性的磁场条件下用穿孔金属板制成的大型电气外壳(SEe)的屏蔽效果,该条件是在混响室(RC)中产生的充分搅拌。通过计算外壳壁的透射横截面(TCS)和内部损耗的吸收横截面(ACSs)进行估算。 TCS和ACS分别连接到墙壁和内部损耗的屏蔽效果(SE)。后者也与外壳内壁的反射率有关。与RC中的测量结果进行的比较足够匹配。它表明这里显示的方法是正确的。此外,结果支持了最近的模型,该模型通过外壳内壁的反射率将SEe连接到SE,并且进一步表明,具有分布孔的空载电气大外壳不是很有效。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号