首页> 外文OA文献 >Application of adaptive non-linear 2D and 3D postprocessing filters for reduced dose abdominal CT
【2h】

Application of adaptive non-linear 2D and 3D postprocessing filters for reduced dose abdominal CT

机译:自适应非线性2D和3D后处理滤波器在减量腹部CT中的应用

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Background: Abdominal computed tomography (an is a frequently performed imaging procedure, resulting in considerable radiation doses to the patient population. Postprocessing filters are one of several dose reduction measures that might help to reduce radiation doses without loss of image quality. less thanbrgreater than less thanbrgreater thanPurpose: To assess and compare the effect of two- and three-dimensional (2D, 3D) non-linear adaptive filters on reduced dose abdominal CT images. less thanbrgreater than less thanbrgreater thanMaterial and Methods: Two baseline abdominal CT image series with a volume computer tomography dose index (CTDI (vol)) of 12 mGy and 6 mGy were acquired for 12 patients. Reduced dose images were postprocessed with 2D and 3D filters. Six radiologists performed blinded randomized, side-by-side image quality assessments. Objective noise was measured. Data were analyzed using visual grading regression and mixed linear models. less thanbrgreater than less thanbrgreater thanResults: All image quality criteria were rated as superior for 3D filtered images compared to reduced dose baseline and 2D filtered images (P andlt; 0.01). Standard dose images had better image quality than reduced dose 3D filtered images (P andlt; 0.01), but similar image noise. For patients with body mass index (BMI) andlt; 30 kg/m(2) however, 3D filtered images were rated significantly better than normal dose images for two image criteria (P andlt; 0.05), while no significant difference was found for the remaining three image criteria (P andgt; 0.05). There were no significant variations of objective noise between standard dose and 2D or 3D filtered images. less thanbrgreater than less thanbrgreater thanConclusion: The quality of 3D filtered reduced dose abdominal CT images is superior compared to reduced dose unfiltered and 2D filtered images. For patients with BMI andlt; 30 kg/m(2), 3D filtered images are comparable to standard dose images.
机译:背景:腹部计算机断层扫描(一种经常执行的成像程序,会给患者群体带来可观的辐射剂量。后处理滤镜是减少剂量的几种措施之一,可有助于减少辐射剂量而不会降低图像质量。目的:评估和比较二维和三维(2D,3D)非线性自适应滤波器对减少剂量的腹部CT图像的影响。小于大于小于小于材质和方法:两个基线腹部CT图像系列12例患者分别获得了12 mGy和6 mGy的体积计算机断层摄影剂量指数(CTDI(vol)),并用2D和3D滤镜对减量剂量图像进行了后处理,六名放射科医生进行了盲目随机,并排图像质量评估。测量噪音,使用视觉分级回归和混合线性模型分析数据。大于结果:与减少剂量的基线和2D滤波图像相比,所有3D滤波图像的图像质量标准均被评为优(P andlt; 0.01)。标准剂量图像具有比减少剂量的3D滤波图像更好的图像质量(P <0.01),但是图像噪声相似。对于体重指数(BMI)为&lt;然而,在30 kg / m(2)的情况下,对于两个图像标准,3D过滤图像的评级显着优于正常剂量图像(P <0.05),而其余三个图像标准(P <0.05)则没有显着差异。在标准剂量和2D或3D滤波图像之间,客观噪声没有明显变化。结论:3D滤波减少剂量的腹部CT图像的质量优于减少剂量未滤波和2D滤波的图像。适用于BMI andlt; 30 kg / m(2)的3D过滤图像与标准剂量图像相当。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号