首页> 外文OA文献 >Comparisons of automated blood pressures in a primary health care setting with self-measurements at the office and at home using the Omron i-C10 device
【2h】

Comparisons of automated blood pressures in a primary health care setting with self-measurements at the office and at home using the Omron i-C10 device

机译:使用Omron i-C10设备将初级卫生保健环境中的自动血压与办公室和家里的自我测量进行比较

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。
获取外文期刊封面目录资料

摘要

OBJECTIVE: We aimed to compare blood pressure (BP) levels recorded using the semiautomatic oscillometric Omron i-C10 BP device in patients with or without hypertension in three different settings: (a) when used by a doctor or a nurse at the office (OBP); (b) when used for self-measurement by the patient at the office (SMOBP); and (c) when used for 7 consecutive days at home (HBP). MATERIALS AND METHODS: A total of 247 individuals were invited to participate, but 78 of these individuals declined and a further seven were excluded, leaving a final cohort of 162 participants. RESULTS: The mean OBP was higher than HBP (difference 8.1±14/3.1±8.8 mmHg, P<0.0001) and so was SMOBP compared with HBP (difference 7.0±13/4.2±7.3 mmHg, P<0.0001). Sixteen participants (9.9%) had at least 10 mmHg higher systolic SMOBP than OBP and 28 (17%) participants had at least 10 mmHg lower systolic SMOBP than OBP. Participants who were current smokers had a larger mean difference between systolic OBP and SMOBP than nonsmokers (OBP-SMOBP in smokers: 6.6±9.4 mmHg, OBP-SMOBP in nonsmokers: 0.5±9.2 mmHg, P=0.011 between groups). CONCLUSION: Self-measurement of BP in the office does not preclude an increase in BP when levels in the individual patients are compared with HBP using the same equipment. Thus, SMOBP with a semiautomatic device does not lead to a reduction in the white-coat effect in the same manner as fully automatic devices.This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivatives 3.0 License, where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially. http://creativecommons.org/licenses/by-nc-nd/3.0.
机译:目的:我们旨在比较使用半自动示波Omron i-C10 BP设备在三种情况下有或没有高血压的患者记录的血压(BP)水平:(a)当医生或护士在办公室使用时(OBP) ); (b)当患者在办公室用于自我测量时(SMOBP); (c)连续7天在家使用(HBP)。材料与方法:共邀请247个人参加,但其中78个人拒绝了参加,另外7个人被排除在外,最终共有162人参加。结果:平均OBP高于HBP(差异8.1±14 / 3.1±8.8 mmHg,P <0.0001),SMOBP也高于HBP(差异7.0±13 / 4.2±7.3 mmHg,P <0.0001)。 16名参与者(9.9%)的收缩期SMOBP比OBP高至少10 mmHg,而28名(17%)参与者的收缩SMOBP至少比OBP低10 mmHg。既往吸烟者的收缩期OBP和SMOBP的平均差异比不吸烟者大(吸烟者的OBP-SMOBP:6.6±9.4 mmHg,不吸烟者的OBP-SMOBP:0.5±9.2 mmHg,组之间P = 0.011)。结论:当使用同一设备将个体患者的水平与HBP进行比较时,办公室中的BP自我测量并不排除BP升高。因此,带有半自动设备的SMOBP不会像全自动设备一样导致白涂层效果的降低。这是根据知识共享署名-非商业性-无衍生工具3.0许可的条款分发的开放获取文章,如果引用正确,则可以下载和共享作品。该作品不能以任何方式更改或用于商业用途。 http://creativecommons.org/licenses/by-nc-nd/3.0。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号