首页> 外文OA文献 >Functional measurements based on feature tracking of cine magnetic resonance images identify left ventricular segments with myocardial scar.
【2h】

Functional measurements based on feature tracking of cine magnetic resonance images identify left ventricular segments with myocardial scar.

机译:基于电影磁共振图像特征跟踪的功能测量可识别出带有心肌疤痕的左心室节段。

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Background The aim of the study was to perform a feature tracking analysis on cine magnetic resonance (MR) images to elucidate if functional measurements of the motion of the left ventricular wall may detect scar defined with gadolinium enhanced MR. Myocardial contraction can be measured in terms of the velocity, displacement and local deformation (strain) of a particular myocardial segment. Contraction of the myocardial wall will be reduced in the presence of scar and as a consequence of reduced myocardial blood flow. Methods Thirty patients (3 women and 27 men) were selected based on the presence or absence of extensive scar in the anteroseptal area of the left ventricle. The patients were investigated in stable clinical condition, 4-8 weeks post ST-elevation myocardial infarction treated with percutaneous coronary intervention. Seventeen had a scar area >75% in at least one anteroseptal segment (scar) and thirteen had scar area <1% (non-scar). Velocity, displacement and strain were calculated in the longitudinal direction, tangential to the endocardial outline, and in the radial direction, perpendicular to the tangent. Results In the scar patients, segments with scar showed lower functional measurements than remote segments. Radial measurements of velocity, displacement and strain performed better in terms of receiver-operator-characteristic curves (ROC) than the corresponding longitudinal measurements. The best area-under-curve was for radial strain, 0.89, where a cut-off value of 38.8% had 80% sensitivity and 86% specificity for the detection of a segment with scar area >50%. As a percentage of the mean, intraobserver variability was 16-14-26% for radial measurements of displacement-velocity-strain and corresponding interobserver variability was 13-12-18%. Conclusion Feature tracking analysis of cine-MR displays velocity, displacement and strain in the radial and longitudinal direction and may be used for the detection of transmural scar. The accuracy and repeatability of the radial functional measurements is satisfactory and global measures agree.
机译:背景技术本研究的目的是对电影磁共振(MR)图像进行特征跟踪分析,以阐明左心室壁运动的功能测量是否可以检测到enhanced增强MR所定义的瘢痕。可以根据特定心肌节段的速度,位移和局部变形(应变)来测量心肌收缩。存在疤痕和心肌血流量减少的结果是,心肌壁的收缩会减少。方法根据左心室前房区是否存在广泛的瘢痕,选择30例患者(3例女性和27例男性)。在经皮冠状动脉介入治疗的ST段抬高型心肌梗死后4-8周,对患者进行了稳定的临床研究。在至少一个前房间隔段(瘢痕)中有十七个的瘢痕面积> 75%,在十三个部位的瘢痕面积<1%(非瘢痕)。沿与心内膜轮廓线相切的纵向和垂直于切线的径向方向计算速度,位移和应变。结果在疤痕患者中,有疤痕的部位的功能测量值低于远端部位。速度,位移和应变的径向测量在接收器-操作员特性曲线(ROC)方面要比相应的纵向测量更好。最好的曲线下面积是径向应变,为0.89,其中临界值38.8%具有80%的灵敏度和86%的特异性,可检测疤痕面积> 50%的部分。以平均百分比的形式,径向测量位移-速度-应变的观察者内部变异性为16-14-26%,而相应的观察者间变异性为13-12-18%。结论cine-MR的特征跟踪分析可显示径向和纵向的速度,位移和应变,可用于检测透壁瘢痕。径向功能测量的准确性和可重复性令人满意,整体测量结果也令人满意。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号