首页> 外文OA文献 >Deriving an Equivalent Circuit of Transformer Insulation for Understanding the Dielectric response Measurements
【2h】

Deriving an Equivalent Circuit of Transformer Insulation for Understanding the Dielectric response Measurements

机译:推导变压器绝缘的等效电路以了解介电响应测量

摘要

Preventive diagnosis and maintenance of transformers have become more and more popular in recent times in order to improve the reliability of electric power systems. Dielectric testing techniques such as return voltage measurement (RVM) and polarization-depolarization current (PDC) measurement are being investigated as potential tools for condition assessment of transformer insulation. A better understanding and analysis of the dielectric test results are only possible with a clear understanding of the physical behavior of the insulation system in response to moisture and aging. A circuit model, which describes the dielectric behavior of the transformeru27s main insulation system, has been parameterized in this paper. The values of the parameters of the model have been identified from the dielectric tests. A correlation has been developed between the physical condition of the insulation and the equivalent model parameters that enable a clear and transparent interpretation of the dielectric test results.
机译:为了提高电力系统的可靠性,近来变压器的预防性诊断和维护变得越来越流行。介电测试技术,例如返回电压测量(RVM)和极化-去极化电流(PDC)测量,正在研究作为评估变压器绝缘状况的潜在工具。只有清楚了解绝缘系统响应水分和老化的物理行为,才能更好地理解和分析介电测试结果。本文已对描述变压器主绝缘系统介电特性的电路模型进行了参数化。模型的参数值已从介电测试中确定。已经在绝缘体的物理条件和等效模型参数之间建立了相关性,从而可以清晰,透明地解释介电测试结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号