Visualization of multimodal polymer-shelled contrast agents using ultrasound contrast sequences: an experimental study in a tissue mimicking flow phantom.

机译:可视化使用超声造影剂序列的多峰聚合物带壳造影剂:模拟流幻影的组织中的实验研究。

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Background\udA multimodal polymer-shelled contrast agent (CA) with target specific potential was recently developed and tested for its acoustic properties in a single element transducer setup. Since the developed polymeric CA has different chemical composition than the commercially available CAs, there is an interest to study its acoustic response when using clinical ultrasound systems. The aim of this study was therefore to investigate the acoustic response by studying the visualization capability and shadowing effect of three polymer-shelled CAs when using optimized sequences for contrast imaging.\ud\udMethods\udThe acoustic response of three types of the multimodal CA was evaluated in a tissue mimicking flow phantom setup by measuring contrast to tissue ratio (CTR) and acoustic shadowing using five image sequences optimized for contrast imaging. The measurements were performed over a mechanical index (MI) range of 0.2-1.2 at three CA concentrations (106, 105, 104 microbubbles/ml).\ud\udResults\udThe CTR-values were found to vary with the applied contrast sequence, MI and CA. The highest CTR-values were obtained when a contrast sequence optimized for higher MI imaging was used. At a CA concentration of 106 microbubbles/ml, acoustic shadowing was observed for all contrast sequences and CAs.\ud\udConclusions\udThe CAs showed the potential to enhance ultrasound images generated by available contrast sequences. A CA concentration of 106 MBs/ml implies a non-linear relation between MB concentration and image intensity.
机译:背景\ ud最近开发了具有目标比电势的多峰聚合物带壳造影剂(CA),并在单元素换能器设置中对其声学特性进行了测试。由于开发的聚合CA具有不同于市售CA的化学成分,因此有兴趣研究使用临床超声系统时的声学响应。因此,本研究的目的是通过研究使用优化序列进行对比成像时三种聚合物壳CA的可视化能力和遮蔽效果来研究声学响应。\ ud \ udMethods \ ud三种类型的多峰CA的声学响应为通过使用针对对比度成像优化的五个图像序列测量对比度与组织之比(CTR)和声学阴影,在模拟流幻影的组织中进行评估。在三种CA浓度(106、105、104微气泡/ ml)的机械指数(MI)范围内进行了测量。\ ud \ ud结果\ ud发现CTR值随所施加的对比序列而变化, MI和CA。当使用针对较高MI成像优化的对比序列时,可获得最高的CTR值。在CA浓度为106微气泡/ ml时,观察到所有对比序列和CA的声学阴影。\ ud \ ud结论\ udCA显示出增强由可用对比序列生成的超声图像的潜力。 CA浓度为106 MBs / ml表示MB浓度与图像强度之间存在非线性关系。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号