首页> 外文OA文献 >Analyse du coup de bélier dans une conduite forcée dans le cas d’une fermeture de vanne. Partie 2: Pertes de charges concentrées en aval
【2h】

Analyse du coup de bélier dans une conduite forcée dans le cas d’une fermeture de vanne. Partie 2: Pertes de charges concentrées en aval

机译:在阀门关闭的情况下对压力水管中的水锤进行分析。第2部分:负载损失集中在下游

摘要

In our previous study (Part 1); by using the graphic of Bergeron, we have drawn the relationships which allow calculating flows and pressures at the valve and the reservoir, considering that pressure losses are negligible. Now, we assume in this second contribution that these pressure losses are concentrated downstream of the pipe, just at the entry of the valve. The study will focus on water hammer-induced by a slow closing of the valve. A practical example will be presented at the end of this work in order to illustrate the exposed method.
机译:在我们之前的研究中(第1部分);通过使用Bergeron的图形,考虑到压力损失可以忽略不计,我们绘制了允许计算阀和油箱处的流量和压力的关系。现在,我们在第二个贡献中假设这些压力损失集中在管道的下游,正好在阀门入口处。该研究将集中在阀门缓慢关闭引起的水锤引起的情况。在此工作的最后将提供一个实际示例,以说明公开的方法。