首页> 外文OA文献 >Heat Transfer Characteristics of Natural Convection within an Enclosure Using Liquid Cooling System.
【2h】

Heat Transfer Characteristics of Natural Convection within an Enclosure Using Liquid Cooling System.

机译:使用液体冷却系统的机壳内自然对流的传热特性。

摘要

In this investigation, a single phase fluid is used to study the coupling between natural convection heat transfer within an enclosure and forced convection through computer covering case to cool the electronic chip. Two working fluids are used (water and air) within a rectangular enclosure and the air flow through the computer case is created by an exhaust fan installed at the back of the computer case. The optimum enclosure size configuration that keeps a maximum temperature of the heat source at a safe temperature level (85℃) is determined. The cooling system is tested for varying values of applied power in the range of 15−40u1d44a.udThe study is based on both numerical models and experimental observations. The numerical work was developed using the commercial software (ANSYS-Icepak) to simulate the flow and temperature fields for the desktop computer and the cooling system. The numerical simulation has the same physical geometry as those used in the experimental investigations. The experimental work was aimed to gather the details for temperature field and use them in the validation of the numerical prediction.udThe results showed that, the cavity size variations influence both the heat transfer process and the maximum temperature. Furthermore, the experimental resultsudiiudcompared favourably with those obtained numerically, where the maximum deviation in terms of the maximum system temperature, is within 3.5%. Moreover, it is seen that using water as the working fluid within the enclosure is capable of keeping the maximum temperature under 77℃ for a heat source of 40u1d44a, which is below the recommended electronic chips temperature of not exceeding 85℃. As a result, the noise and vibration level is reduced. In addition, the proposed cooling system saved about 65% of the CPU fan power.
机译:在这项研究中,使用单相流体来研究外壳内自然对流传热与通过计算机外壳进行强制对流以冷却电子芯片之间的耦合。在矩形外壳内使用了两种工作流体(水和空气),并且通过安装在计算机机箱背面的排气扇产生了通过计算机机箱的气流。确定将热源的最高温度保持在安全温度水平(85℃)的最佳外壳尺寸配置。对冷却系统进行了测试,测试了所施加功率在15−40 u1d44a.ud中的变化值。该研究基于数值模型和实验观察。使用商用软件(ANSYS-Icepak)开发了数值工作,以模拟台式计算机和冷却系统的流场和温度场。数值模拟具有与实验研究中使用的相同的物理几何形状。实验工作旨在收集温度场的详细信息,并将其用于数值预测的验证中。 ud结果表明,空腔尺寸的变化会影响传热过程和最高温度。此外,实验结果与以数字方式获得的结果(在最大系统温度方面的最大偏差在3.5%以内)相比是有利的。此外,可以看出,对于40℃的热源,使用水作为外壳内的工作流体能够将最高温度保持在77℃以下,该温度低于建议的电子芯片温度不超过85℃。结果,降低了噪声和振动水平。此外,建议的冷却系统节省了约65%的CPU风扇功率。

著录项

  • 作者

    Gdhaidh Farouq Ali S.;

  • 作者单位
  • 年度 2015
  • 总页数
  • 原文格式 PDF
  • 正文语种 en
  • 中图分类

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号