Assessment of stereoscopic optic disc images using an autostereoscopic screen: an experimental study

机译:使用自动立体屏幕评估立体视盘图像:一项实验研究

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Background\udStereoscopic assessment of the optic disc morphology is an important part of the care of patients with glaucoma. The aim of this study was to assess stereoviewing of stereoscopic optic disc images using an example of the new technology of autostereoscopic screens compared to the liquid shutter goggles.\ud\udMethods\udIndependent assessment of glaucomatous disc characteristics and measurement of optic disc and cup parameters whilst using either an autostereoscopic screen or liquid crystal shutter goggles synchronized with a view switching display. The main outcome measures were inter-modality agreements between the two used modalities as evaluated by the weighted kappa test and Bland Altman plots.\ud\udResults\udInter-modality agreement for measuring optic disc parameters was good [Average kappa coefficient for vertical Cup/Disc ratio was 0.78 (95% CI 0.62–0.91) and 0.81 (95% CI 0.6–0.92) for observer 1 and 2 respectively]. Agreement between modalities for assessing optic disc characteristics for glaucoma on a five-point scale was very good with a kappa value of 0.97.\ud\udConclusion\udThis study compared two different methods of stereo viewing. The results of assessment of the different optic disc and cup parameters were comparable using an example of the newly developing autostereoscopic display technologies as compared to the shutter goggles system used. The Inter-modality agreement was high. This new technology carries potential clinical usability benefits in different areas of ophthalmic practice.
机译:背景\立体镜检查视盘形态是青光眼患者护理的重要组成部分。这项研究的目的是使用自动立体屏幕的新技术实例(与液体百叶窗护目镜相比)来评估立体视盘图像的立体观察。\ ud \ udMethods \ ud对青光眼盘特征的独立评估以及视盘和杯形参数的测量同时使用与视图切换显示同步的自动立体屏幕或液晶快门护目镜。主要结果指标是通过加权kappa检验和Bland Altman图评估的两个使用的模态之间的模态一致性。\ ud \ udResults \ ud用于测量视盘参数的模态一致性很好[垂直杯/杯的平均kappa系数/观察者1和2的椎间盘比率分别为0.78(95%CI 0.62-0.91)和0.81(95%CI 0.6-0.92)。在五点量表上评估青光眼视盘特征的模态之间的一致性非常好,kappa值为0.97。\ ud \ ud结论\ ud本研究比较了两种不同的立体观看方法。使用新开发的自动立体显示技术的示例,与使用的百叶窗护目镜系统相比,评估不同光盘和杯形参数的结果具有可比性。多式联运协议很高。这项新技术在眼科实践的不同领域具有潜在的临床实用性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号