首页> 外文OA文献 >Development of a Procedure to Measure the Effectiveness of Electret N-95 Respirator Filter Media for Capturing Nano-Particles
【2h】

Development of a Procedure to Measure the Effectiveness of Electret N-95 Respirator Filter Media for Capturing Nano-Particles

机译:开发一种用于测量驻极体N-95呼吸器过滤介质捕获纳米颗粒效果的程序

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The phenomenal growth of the nano-technological products and their impacts on our society led government organizations and scientists to consider the risks related to human exposure to nano-particles (NPs). As a precautionary approach, respiratory protection is suggested for workers to reduce their exposure to NPs. Thus, it is important to characterize the performance of these respirators to capture NPs.udIn this study, the performance of one model of N95 respirators was characterized against poly and mono-disperse NPs. With poly-disperse NPs, a methodology was developed to measure the performance of the N95 respirators against NaCl aerosols in the size range of 15 to 200 nm in three scenarios. The N95 respirator performance was also characterized at 85 liters/min against twelve mono-size aerosols with size ranging from 20 to 200 nm. udUsing poly-disperse aerosols test (PAT) method; the results demonstrated that the initial penetration was significantly enhanced with the increased airflows and a shift toward small particle size was observed for the most penetrating particle size (MPPS). For particles below 100 nm, the penetration decreased with further loading. The MPPS was also found to shift toward the large sized particles. In addition, the penetration augmented slightly as the (RH) increased.udUsing mono-disperse aerosol test (MAT) method; the results revealed the initial particle penetration is less than 5% NIOSH certification criterion. However, it was found that the initial value, measured with (MAT) method, is not related with the initial penetration measured with (PAT) method at each corresponding particle size at 85 liters/min.ud
机译:纳米技术产品的迅猛发展及其对我们社会的影响,促使政府组织和科学家考虑了与人类接触纳米颗粒(NPs)相关的风险。作为一种预防措施,建议为工人提供呼吸防护,以减少其对NP的暴露。因此,表征这些呼吸器捕获NP的性能非常重要。 ud在这项研究中,针对多和单分散NP表征了一种N95呼吸器模型的性能。使用多分散NP,在三种情况下,开发了一种方法来测量N95呼吸器对15至200 nm大小的NaCl气溶胶的性能。 N95防毒面具的性能还针对85升/分钟的特征,针对12种尺寸为20至200 nm的单一尺寸的气溶胶。 使用多分散气溶胶测试(PAT)方法;结果表明,随着气流的增加,初始渗透率显着提高,并且观察到最大穿透性粒径(MPPS)向小粒径转变。对于低于100 nm的颗粒,渗透率会随着进一步的加载而降低。还发现MPPS向大尺寸颗粒移动。此外,渗透率随(RH)的增加而略有增加。 ud采用单分散气溶胶测试(MAT)方法;结果表明,初始颗粒渗透率小于5%的NIOSH认证标准。但是,发现在每种相应的粒径为85升/分钟时,用(MAT)方法测得的初始值与(PAT)方法测得的初始渗透率无关。

著录项

  • 作者

    Mostofi Darbani Reza;

  • 作者单位
  • 年度 2010
  • 总页数
  • 原文格式 PDF
  • 正文语种 en
  • 中图分类

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号