首页> 外文OA文献 >Performance tests of the LCA- ECS heat exchanger duct withudsimulation of primary heat exchanger pressure dropududud
【2h】

Performance tests of the LCA- ECS heat exchanger duct withudsimulation of primary heat exchanger pressure dropududud

机译:具有 ud的LCA- ECS热交换器管道的性能测试换热器压降的模拟 ud ud ud

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Total pressure drop in the inlet and outlet ductingudof the LCA-ECS primary heat exchanger were determined corresponding to flight Mach numbers upto 0.86. A suitable screen/wire mesh was selected whose pressure loss characteristics matched with those of the primary heat exchanger being procured for use with LCA. The flow through the duct at low inlet Mach numbers was augmented using a suitable ejector. The inlet duct pressure loss was found to be nearly 60% higher than that due to the heat exchanger alone. The ram air and ejector air temperatures were simulated as per flight conditions and their effects were studied.
机译:确定了LCA-ECS一级热交换器的入口和出口导管中的总压降,对应于高达0.86的飞行马赫数。选择合适的筛网/丝网,其压力损失特性与要与LCA一起使用的一次热交换器的压力损失特性相匹配。使用合适的喷射器增加了低马赫数时通过管道的流量。发现入口管道压力损失比仅由于热交换器导致的损失高近60%。根据飞行条件模拟冲压空气和喷射器空气的温度,并研究其影响。