Validated extraction of gait sub-phase durations using an ambulatory accelerometer-based system is a current unmet need to quantify subtle changes during the walking of older adults. In this paper, we describe (1) a signal processing algorithm to automatically extract not only durations of stride, stance, swing, and double support phases, but also durations of sub-phases that refine the stance and swing phases from foot-worn accelerometer signals in comfortable walking of older adults, and (2) the validation of this extraction using reference data provided by a gold standard system. The results show that we achieve a high agreement between our method and the reference method in the extraction of (1) the temporal gait events involved in the estimation of the phase/sub-phase durations, namely heel strike (HS), toe strike (TS), toe-off (TO), maximum of heel clearance (MHC), and maximum of toe clearance (MTC), with an accuracy and precision that range from ‒3.6 ms to 4.0 ms, and 6.5 ms to 12.0 ms, respectively, and (2) the gait phase/sub-phase durations, namely stride, stance, swing, double support phases, and HS to TS, TO to MHC, MHC to MTC, and MTC to HS sub-phases, with an accuracy and precision that range from ‒4 ms to 5 ms, and 9 ms to 15 ms, respectively, in comfortable walking of a thirty-eight older adults ( (mean ± standard deviation) 71.0 ± 4.1 years old). This demonstrates that the developed accelerometer-based algorithm can extract validated temporal gait events and phase/sub-phase durations, in comfortable walking of older adults, with a promising degree of accuracy/precision compared to reference data, warranting further studies.
机译:使用基于移动式加速度计的系统对步态亚阶段持续时间进行有效提取是当前量化老年人行走过程中细微变化的需求。在本文中,我们描述(1)一种信号处理算法,该算法不仅可以自动提取步幅,姿势,挥杆和双支撑阶段的持续时间,还可以从脚踏加速度计中自动提取可改善姿势和挥杆相位的子阶段的持续时间在老年人舒适行走时发出信号,以及(2)使用黄金标准系统提供的参考数据对该提取进行验证。结果表明,我们的方法与参考方法在(1)估计阶段/亚阶段持续时间即脚跟打击(HS),脚趾打击( TS),脚趾离开(TO),最大脚跟间隙(MHC)和最大脚趾间隙(MTC),其准确度和精密度分别为‒3.6 ms至4.0 ms和6.5 ms至12.0 ms (2)步态阶段/子阶段的持续时间,即步幅,姿势,挥杆,双支撑阶段以及从HS到TS,从TO到MHC,从MHC到MTC以及从MTC到HS的子阶段,准确度和在38个老年人的舒适行走中((平均±标准偏差)71.0±4.1岁),其精确度分别为‒4 ms至5 ms和9 ms至15 ms。这表明,开发的基于加速度计的算法可以在老年人舒适行走时提取经过验证的时间步态事件和相/亚相持续时间,与参考数据相比,其有希望的准确性/精密度,值得进一步研究。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号